SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
401
2 Parameters
2.2 List of parameters
Description:
Display and connector output for the position setpoint after setpoint smoothing.
Description:
Display and connector output for the difference between the position setpoint and the position actual value at the
position controller input.
Description:
Display and connector output for the P component at the output of the position controller (speed setpoint).
Description:
Display and connector output for the I component at the output of the position controller (speed setpoint).
Description:
Display and connector output for the speed setpoint after limiting (CI: p2541).
r2556
CO: LR position setpoint after setpoint smoothing / s_set after interp
CU250S_V (Position
control)
CU250S_V_CAN
(Position control)
CU250S_V_DP
(Position control)
CU250S_V_PN
(Position control)
Access level:
1
Calculated:
-
Data type:
Integer32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4015
Min Max
Factory
setting
- [LU]
- [LU]
- [LU]
r2557
CO: LR position controller input system deviation / LR_inp sys dev
CU250S_V (Position
control)
CU250S_V_CAN
(Position control)
CU250S_V_DP
(Position control)
CU250S_V_PN
(Position control)
Access level:
1
Calculated:
-
Data type:
Integer32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4015
Min Max
Factory
setting
- [LU]
- [LU]
- [LU]
r2558
CO: LR position controller output P component / LR_outp P comp
CU250S_V (Position
control)
CU250S_V_CAN
(Position control)
CU250S_V_DP
(Position control)
CU250S_V_PN
(Position control)
Access level:
1
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
p2000
Dyn. index:
-
Unit group:
3_1
Unit selection:
p0505
Func. diagram:
4015
Min Max
Factory
setting
- [rpm]
- [rpm]
- [rpm]
r2559
CO: LR position controller output I component / LR_outp I comp
CU250S_V (Position
control)
CU250S_V_CAN
(Position control)
CU250S_V_DP
(Position control)
CU250S_V_PN
(Position control)
Access level:
1
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
p2000
Dyn. index:
-
Unit group:
3_1
Unit selection:
p0505
Func. diagram:
4015
Min Max
Factory
setting
- [rpm]
- [rpm]
- [rpm]
r2560
CO: LR speed setpoint / n_set
CU250S_V (Position
control)
CU250S_V_CAN
(Position control)
CU250S_V_DP
(Position control)
CU250S_V_PN
(Position control)
Access level:
1
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
p2000
Dyn. index:
-
Unit group:
3_1
Unit selection:
p0505
Func. diagram:
4015
Min Max
Factory
setting
- [rpm]
- [rpm]
- [rpm]