2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
456
List Manual, 09/2017, A5E33842890
For bit 04 = 1:
The plus limit switch reached.
For bit 05 = 1:
The minus limit switch reached.
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the n coordinate of the 1st value pair of the friction characteristic.
Dependency:
Refer to: p3830, p3845
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the n coordinate of the 2nd value pair of the friction characteristic.
Dependency:
Refer to: p3831, p3845
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the n coordinate of the 3rd value pair of the friction characteristic.
Dependency:
Refer to: p3832, p3845
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the n coordinate of the 4th value pair of the friction characteristic.
Dependency:
Refer to: p3833, p3845
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the n coordinate of the 5th value pair of the friction characteristic.
p3820[0...n]
Friction characteristic value n0 / Friction n0
Access level:
2
Calculated:
p0340 = 1,3,5
Data type:
FloatingPoint32
Can be changed:
T
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
3_1
Unit selection:
p0505
Func. diagram:
7010
Min Max
Factory
setting
0.00 [rpm]
210000.00 [rpm]
15.00 [rpm]
p3821[0...n]
Friction characteristic value n1 / Friction n1
Access level:
2
Calculated:
p0340 = 1,3,5
Data type:
FloatingPoint32
Can be changed:
T
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
3_1
Unit selection:
p0505
Func. diagram:
7010
Min Max
Factory
setting
0.00 [rpm]
210000.00 [rpm]
30.00 [rpm]
p3822[0...n]
Friction characteristic value n2 / Friction n2
Access level:
2
Calculated:
p0340 = 1,3,5
Data type:
FloatingPoint32
Can be changed:
T
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
3_1
Unit selection:
p0505
Func. diagram:
7010
Min Max
Factory
setting
0.00 [rpm]
210000.00 [rpm]
60.00 [rpm]
p3823[0...n]
Friction characteristic value n3 / Friction n3
Access level:
2
Calculated:
p0340 = 1,3,5
Data type:
FloatingPoint32
Can be changed:
T
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
3_1
Unit selection:
p0505
Func. diagram:
7010
Min Max
Factory
setting
0.00 [rpm]
210000.00 [rpm]
120.00 [rpm]
p3824[0...n]
Friction characteristic value n4 / Friction n4
Access level:
2
Calculated:
p0340 = 1,3,5
Data type:
FloatingPoint32
Can be changed:
T
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
3_1
Unit selection:
p0505
Func. diagram:
7010
Min Max
Factory
setting
0.00 [rpm]
210000.00 [rpm]
150.00 [rpm]