2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
480
List Manual, 09/2017, A5E33842890
Help for error value = 35:
- Reset parameter p4691 to 30.
Help for error value = 37:
- set the access level to Expert or higher.
Help for error value = 38:
- insert the SMI/DQI into the actual topology as an additional component (component number >= 200).
- set the component number from the actual topology (p4690 >= 200).
- set the correct component number (p4690 >= 200).
Note for error value = 39:
- SMI already deleted or too old. Delete not possible.
Description:
Setting to back up the data of all SMIs and DQIs featured in the target topology.
Value:
0:
Inactive
1:
Save data of all SMIs and DQIs
10:
Save all data successful
13:
Insufficient memory space for backup
16:
Transfer fault during data backup
20:
Component does not contain any data
29:
Not all components from target topology saved
Note:
SMI: SINAMICS Sensor Module Integrated
p4692 = 10: Automatic on successful completion of backup procedure.
p4692 = 13, 16, 20, 29: Error values if the procedure could not be executed successfully.
The procedure must be repeated if the data save operation was interrupted (e.g. if the power supply voltage failed).
Help for error value = 13:
- Use a memory card with more memory space.
Help for error value = 16:
- check the DRIVE-CLiQ wiring.
Remedy for fault value = 20:
- Use an SMI that is not blank.
Help for error value = 29:
- check and correct the target and actual topologies for the SMIs.
- Repeat the save procedure.
Description:
Sets the directory for downloading and saving data.
Example:
The SMI has the component number 5 and the SMI data (motor/encoder data) is to be stored in subdirectory C205.
--> p4690 = 5, p4693[0] = 205, p4691 = 1
Index:
[0] = Subdirectory selection
[1] = Reserved
Dependency:
Refer to: p4691, r4694
p4692
SMI spare part save data of all SMIs / Save SMI data
Access level:
1
Calculated:
-
Data type:
Integer16
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 29
0
p4693[0...1]
SMI spare part data backup directory / SMI dat_bkup dir
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 399
0