2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
488
List Manual, 09/2017, A5E33842890
Description:
Sets the general properties for energy-saving.
Note:
Pe: PROFIenergy profiles
PROFIdrive state S4: operation
Description:
Sets the mode-dependent properties for energy-saving.
Index:
[0] = Reserved
[1] = Mode 2
Note:
Pe: PROFIenergy profiles
Description:
Display and binector output for the state display PROFIenergy energy saving active or inactive.
Note:
Bit 0 and bit 1 are inverse of one another.
Pe: PROFIenergy profiles
Description:
Sets the signal source to set in the PROFIdrive state S1 "switching-on inhibited".
Dependency:
Refer to: r5613
Note:
Pe: PROFIenergy profiles
p5611
Pe energy-saving properties general / Pe properties gen
CU250S_V_PN
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2381, 2382
Min Max
Factory
setting
- - 0000
bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Inhibit PROFIenergy control commands
Yes
No
-
01
Drive initiates OFF1 when transitioning to
energy-saving mode
Yes
No
-
02
Trans to energy-saving mode from
PROFIdrive state S3/4 poss
Yes
No
-
p5612[0...1]
Pe energy-saving properties mode-dependent / Pe properties mod
CU250S_V_PN
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - [0]
0110
bin
[1] 0000 bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Reserved
Yes
No
-
r5613.0...1
CO/BO: Pe energy-saving active/inactive / Pe save act/inact
CU250S_V_PN
Access level:
3
Calculated:
-
Data type:
Unsigned8
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2382
Min Max
Factory
setting
- - -
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Pe active
Yes
No
-
01
Pe inactive
Yes
No
-
p5614
BI: Pe set switching-on inhibited signal source / Pe sw-on_inh s_src
CU250S_V_PN
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2382
Min Max
Factory
setting
- - 0