2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
400
List Manual, 09/2017, A5E33842890
Description:
Sets the signal source for the signal "travel to fixed stop active".
BI: p2552 = 1 signal:
The activity associated with travel to fixed stop is signaled and the detection of the fixed stop is started via the
maximum following error (p2634).
Dependency:
Refer to: r2683
Description:
Sets the signal source for the signal "fixed stop reached".
BI: p2553 = 1 signal:
When the fixed stop is reached, this is signaled and the fixed stop monitoring window is activated.
Dependency:
Refer to: r2683
Description:
Sets the signal source for the signal "traversing command active".
BI: p2554 = 1 signal:
It is signaled that positioning is active and therefore the positioning monitoring is not activated with the signal
"setpoint fixed" (p2551).
Dependency:
Refer to: p2551, r2684
Description:
Sets the signal source for the reference of the internal length units LU to motor revolution for rotary encoders and to
mm for linear encoders.
Dependency:
Refer to: p0404, r2524
Note:
The signal value is used to convert the length unit to the speed or velocity setpoint.
p2552
BI: LR signal travel to fixed stop active / Signal TfS act
CU250S_V (Position
control)
CU250S_V_CAN
(Position control)
CU250S_V_DP
(Position control)
CU250S_V_PN
(Position control)
Access level:
1
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4025
Min Max
Factory
setting
- - 2683.14
p2553
BI: LR signal fixed stop reached / Signal fixed stop
CU250S_V (Position
control)
CU250S_V_CAN
(Position control)
CU250S_V_DP
(Position control)
CU250S_V_PN
(Position control)
Access level:
1
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4025
Min Max
Factory
setting
- - 2683.12
p2554
BI: LR signal traversing command active / Sig trav_cmnd act
CU250S_V (Position
control)
CU250S_V_CAN
(Position control)
CU250S_V_DP
(Position control)
CU250S_V_PN
(Position control)
Access level:
1
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4020
Min Max
Factory
setting
- - 2684.15
p2555
CI: LR LU/revolution LU/mm / LU/rev LU/mm
CU250S_V (Position
control)
CU250S_V_CAN
(Position control)
CU250S_V_DP
(Position control)
CU250S_V_PN
(Position control)
Access level:
3
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4015
Min Max
Factory
setting
- - 2524[0]