2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
120
List Manual, 09/2017, A5E33842890
Description:
Sets the bearing version.
Corresponding to the bearing version entered, its code number (p0531) is automatically set.
0 = No data
1 = Manual entry
101 = STANDARD
102 = PERFORMANCE
103 = HIGH PERFORMANCE
104 = ADVANCED LIFETIME
Dependency:
Refer to: p0301, p0531, p0532, p1082
Notice:
For p0530 = 101, 102, 103, 104, the maximum bearing speed (p0532) is write protected. Write protection is
withdrawn with p0530 = 1.
If p0530 is changed during quick commissioning (p0010 = 1), then the maximum speed p1082, which is also
associated with quick commissioning, is pre-assigned appropriately. This is not the case when commissioning the
motor (p0010 = 3). The maximum speed of the bearing is factored into the limit for the maximum speed p1082.
Note:
For a motor with DRIVE-CLiQ, p0530 can only be set to 1.
Description:
Display and setting the code number of the bearing.
When setting p0301 and p0530 the code number is automatically pre-assigned and is write protected. The
information in p0530 should be observed when removing write protection.
Dependency:
Refer to: p0301, p0530, p0532, p1082
Notice:
If p0531 is changed during quick commissioning (p0010 = 1), then the maximum speed p1082, which is also
associated with quick commissioning, is pre-assigned appropriately. This is not the case when commissioning the
motor (p0010 = 3). The maximum speed of the bearing is factored into the limit for the maximum speed p1082.
Note:
p0531 cannot be changed on a motor with DRIVE-CLiQ.
Description:
Sets the maximum speed of the bearing.
The following applies when calculating the maximum speed (p1082):
- for p0324 = 0 or p0532 = 0, p0322 is used.
- for p0324 > 0 and p0532 > 0, the minimum value from the two parameters is used.
Dependency:
Refer to: p0301, p0322, p0530, p1082
p0530[0...n]
Bearing version selection / Bearing vers sel
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
C(1, 3)
Scaling:
-
Dyn. index:
MDS
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 104
0
p0531[0...n]
Bearing code number selection / Bearing codeNo sel
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
C(3)
Scaling:
-
Dyn. index:
MDS
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 65535
0
p0532[0...n]
Bearing maximum speed / Bearing n_max
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
C(1, 3)
Scaling:
-
Dyn. index:
MDS
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0.0 [rpm]
210000.0 [rpm]
0.0 [rpm]