SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
573
2 Parameters
2.2 List of parameters
Note:
This parameter is only supplied with actual values if SI Motion functions are active. For Safety Integrated Basic
Functions (STO), the value is equal to zero.
Description:
Displays the diagnostic signals for safety-relevant motion monitoring functions integrated in the drive.
Note:
For bit 01:
This bit can be used to execute a control-based ESR.
ESR: Extended Stop and Retract
SAM: Safe Acceleration Monitor (safe acceleration monitoring)
SBR: Safe Brake Ramp (safe brake ramp monitoring)
Description:
Displays the cross-check comparison clock cycle.
The value indicates the clock cycle time with which each individual KDV value is compared between the two
monitoring channels.
Note:
KDV: Data cross-check
Description:
For index 0:
Displays the message value that resulted in the STOP F on the drive.
Value = 0:
Processor 1 signaled a STOP F.
Value = 1 ... 999:
Number of the incorrect date in the data cross-check between the monitoring channels.
Value >= 1000:
Additional diagnostic values of the drive.
For index 1:
Displays the value from processor 1 that resulted in the STOP F.
For index 2:
Displays the value from processor 2 that resulted in the STOP F.
r9723.0...16
CO/BO: SI Motion diagnostic signals integrated in the drive / SI Mtn integ diag
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Forced checking procedure required
Yes
No
-
01
STOP F and then STOP B active
Yes
No
2819
02
Communication failure
Yes
No
-
03
Actual value sensing supplies valid value
Yes
No
2821
04
Encoderless act val sensing acc to
technique for U/f control
Yes
No
-
09
Safe pulse suppression active
Yes
No
-
12
Test stop active
Yes
No
-
16
SAM/SBR active
Yes
No
2820
r9724
SI Motion cross-check comparison clock cycle / SI Mtn KDV clk cyc
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- [ms]
- [ms]
- [ms]
r9725[0...2]
SI Motion diagnostics STOP F / SI Mtn Diag STOP F
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -