SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
475
2 Parameters
2.2 List of parameters
Description:
Sets the voltage when the connected sensor is at actual value zero.
At this voltage channel B supplies an actual value of zero.
Description:
Sets the output voltage range to be mapped for the connected analog sensor.
The voltage range is determined by the following parameters:
- p4674 (voltage at actual value 0)
- p4675 (voltage per encoder period)
Note:
The minimum actual value which can be mapped is equal to p4674 - p4675/2.
The maximum actual value which can be mapped is equal to p4674 + p4675/2.
Description:
Sets the threshold for limit monitoring of the absolute actual value on the analog sensor.
If this threshold is overshot by the actual value of a channel, a corresponding fault/alarm (p4670.9) is output.
Dependency:
Refer to: p4673, p4675
Description:
Sets the configuration for LVDT mode on the analog sensor.
Description:
Sets the ratio for the LVDT sensor.
p4674[0...n]
Analog sensor channel B voltage at actual value zero / Ana_sens B U at 0
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
EDS, p0140
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
-10.0000 [V]
10.0000 [V]
0.0000 [V]
p4675[0...n]
Analog sensor channel B voltage per encoder period / Ana_sens B U/per
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
EDS, p0140
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
-10.0000 [V]
10.0000 [V]
6.0000 [V]
p4676[0...n]
Analog sensor range limit threshold / Ana_sens lim thr
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
EDS, p0140
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0.0 [%]
100.0 [%]
100.0 [%]
p4677[0...n]
Analog sensor LVDT configuration / Ana_sens LVDT conf
Access level:
4
Calculated:
-
Data type:
Unsigned32
Can be changed:
C(4)
Scaling:
-
Dyn. index:
EDS, p0140
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - 0000
bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
LVDT ON
Yes
No
-
01
Track B excitation
Yes
No
-
02
Fixed value amplitude
Yes
No
-
03
Fixed value amplitude and phase
Yes
No
-
p4678[0...n]
Analog sensor LVDT ratio / An_sens LVDT ratio
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
C(4)
Scaling:
-
Dyn. index:
EDS, p0140
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0.00 [%]
200.00 [%]
50.00 [%]