background image

Scene Capable Plug-In Appliance Module

Cat. No. VRP15-1LW

Incandescent: 1800W      Fluorescent: 1800VA 

Resistive: 15A     Motor: 1/2HP

Rated: 120VAC, 60Hz

INSTALLATION INSTRUCTIONS

DI-030-VRP15-02A-X1

 INTRODUCTION

Leviton’s V

TM

 components are 

designed to communicate with each other 

via Radio Frequency (RF) to provide remote 

control of your lighting. Using RF technology 

allows Leviton to provide the greatest signal 

integrity possible. Each module in Leviton’s 

Vizia RF +

TM

 component line is a Z-Wave

®

 

enabled device. In a Z-Wave

®

 network, each 

device is designed to act as a router. These 

routers will re-transmit the RF signal from one 

device to another until the intended device 

is reached. This ensures that the signal is 

received by its intended device by routing the 

signal around obstacles and radio dead spots.

CAUTION:

Remember to exercise good common sense 

when using the Timer features of your remote, 

especially when scheduling unattended 

devices. There can be some unexpected 

consequences if not used with care. For 

example, an empty coffee pot can be remotely 

turned on. If that should happen, your coffee 

pot could be damaged from overheating. If an 

electric heater is turned on by remote control 

while clothing is draped over it, a fire could 

result. 

DO NOT USE

 the remote for the control 

of high power heating appliances such as 

portable heaters. 

DO NOT 

change location 

after unit is enrolled in Z-wave

®

 network.

NOTES:

•  If using a non-Leviton Programmer/Remote, 

refer to the Programmer/Remote instruction 

sheet for including a device.

•  If using VRCPG install checklist go directly to 

step B.

A)

 If using a Leviton Z-Wave

®

 Programmer/

Remote, Cat. No. VRCPG, press the Menu 

button and scroll down to System. Press the 

center button to select System Menu. Choose 

Advanced. Press the center button to select 

Advanced Install.

Including Scene Capable 

Plug-In Appliance Module 

into Z-Wave

®

 Network:

 

Step 3

Attaching Scene Capable 

Plug-In Appliance Module to 

Wall Receptacle:

 

Step 2

•  Plug the Scene Capable Plug-in Appliance 

Module into wall receptacle. Verify that 

receptacle is live. If controlled by a wall switch, 

the switch 

must be kept ON

 at all times.

Attaching Load to Scene 

Capable Plug-In Appliance 

Module:

 

Step 1

NOTE:

 In order to use your Vizia RF +

TM

 Scene 

Capable Plug-In Appliance Module in a Z-Wave

®

 

network, it must be included in the network using 

a Primary Programmer/Remote, such as Leviton’s 

Cat. No. VRCPG. Before including your module, 

please refer to the Primary Programmer/Remote 

instruction sheet for complete information. 

Refer 

to Step 3 for further details

.

•  Locate load to be controlled by Scene Capable 

Plug-In Appliance Module and ensure it is 

fully operational. Attach load plug into module 

receptacle noting proper polarity of blades.

NOTE:

 Use check boxes           when Steps are 

completed.

INSTALLING YOUR APPLIANCE MODULE

B)

 While standing close to the module 

(approximately 1 foot), press the center 

button to <Include> device in the network.

 

NOTE:

 Only one device may be included 

at a time. 

DO NOT

 put multiple devices into 

the Inclusion mode at any time.

C)

 While the Programmer/Remote is in the 

Inclusion mode and the LED is ON on 

the Scene Capable Plug-In Appliance 

Module, press the ON/OFF button on the 

module. The Programmer/Remote will verify 

inclusion and the LED will turn OFF on the 

Scene Capable Plug-In Appliance Module.

 

NOTE:

 If the LED on the Scene Capable 

Plug-In Appliance Module turns solid 

Red while including, there has been 

a communication error. 

Refer to 

Troubleshooting section.

D)

 The Primary Programmer/Remote will 

assign a node ID number (Name) for this 

module.

 

NOTE:

 This ID number (Name) will be 

stored in the controller to be used for future 

reference.

 

NOTE:

 You may name or edit this device at 

this time.

E)

 

The module is now installed in the 

network

.

NOTE:

 If the module has been successfully 

included in the network and the user tries to 

include it again without first excluding it from 

the network, the module will retain the first 

node ID it had received and ignore the second.

•   Switch ON/OFF

•   Scene capable

•   ON/OFF LED

•   Two way communication

•   RF reliability

•   Ease of installation – No new wiring

•   Compatible with other Z-Wave

®

 enabled 

devices

 FEATURES

 

Step 2 cont’d

 

Step 3 cont’d

Programming and 

ON/OFF Button

ON

ON

ON

ON

OFF

OFF

OFF

OFF

Programmer/Remote

Cat. No. VRCPG

Center Button

Menu Button

WARNINGS AND CAUTIONS:

•  To be installed and/or used in accordance with appropriate electrical codes and regulations.

•  If you are unsure about any part of these instructions, consult an electrician.

WARNINGS AND CAUTIONS:

•  Unplug unit when servicing fixture or changing bulbs.

•  Save this instruction sheet. It contains important technical data along with testing and 

troubleshooting information which will be useful after installation is complete.

Reviews: