background image

      EVP/NC 

DESCRIPTION

Gas interception automatic normally closed solenoid 

valves that open when the coil is powered and close 

when there is no tension.

These solenoid valves can be controlled by pressure 

switch, thermostat, etc.

They can be equipped with a fl ow regulator and 

adjustable slow opening kit.

EC certifi ed according to EN 161 

In  conformity  with  the  2009/142/EC 

Directive (Gas Directive)

In  conformity  with  the  94/9/EC  Directive 

(ATEX Directive)

In conformity with the 2004/108/EC Directive 

(Electromagnetic Compatibility)

In conformity with the 2006/95/EC Directive 

(Low Voltage)

II 3G - II 3D

MADAS-01

0051

Summary of Contents for EVP/NC

Page 1: ...ch thermostat etc They can be equipped with a flow regulator and adjustable slow opening kit EC certified according to EN 161 In conformity with the 2009 142 EC Directive Gas Directive In conformity w...

Page 2: ...Environment temperature 15 60 C Max superficial temperature 85 C Protection degree IP65 Class DN 15 DN 150 A DN 200 B Group 2 Closing time 1 s Opening time 1 s Coils poliammidic resin encapsulated wi...

Page 3: ...32 003 110 V 50 Hz EVP05 002 EVP32 002 230 V 50 60 Hz EVP05 008 EVP32 008 EVP NC DN 40 12 Vdc EVP06 001 EVP40 001 24 Vdc EVP06 005 EVP40 005 24 V 50 Hz EVP06 003 EVP40 003 110 V 50 Hz EVP06 002 EVP40...

Page 4: ...spring 4 Body valve 5 Obturator 6 Seal washer 7 G 1 4 cap 8 Filter 9 Fixing screws 10 Cover or bottom 11 Electrical coil 12 Coil fixing nut or screw 13 Flow calibration screw EVPF version 14 Bottom o...

Page 5: ...Capacity diagram EVP NC P max 360 mbar 1 metano 2 aria 3 gas di citt 4 gpl 1 methane 2 air 3 town gas 4 lpg e e ne o...

Page 6: ...cause an explosive atmosphere WARNING all installation wiring maintenance work must be carried out by skilled staff The gas supply must be shut off before installation Check that the line pressure DO...

Page 7: ...on the screw 16 This screw has not limit the opening speed increases gradually screwing clockwise the screw 16 To regulate the rapide stroke operate on the screw 15 Screwing counterclockwise till the...

Page 8: ...ntrol rete pipe r seau red utenza user utilisateur punto de consumo rete pipe r seau red EXAMPLE OF INSTALLATION 2 1 Gas filter type FM 2 Over pressure slam shut off valve type MVB1 MAX 3 Gas pressure...

Page 9: ...seefig 3 4 5 6 unscrew the nut 12 or the slow opening kit 17 and remove the coil 11 Unscrew the fixing screws 9 and with care take the cover 10 off the body 4 of the valve then control the obturator...

Page 10: ...12V RAC ES CN 2110 RADDRIZZATORE Energy Saving RECTIFIER Energy Saving 24 Vdc BO 0417 BO 0417 24V RAC ES CN 2100 NORMALE Energy Saving NORMAL Energy Saving 24 V 50 Hz BO 0417 BO 0417 24V RAC ES CN 21...

Page 11: ...rgy Saving DN 65 DN 80 P max 360 mbar 24 Vdc BO 1110 24 Vdc DN 65 80 CN 2000 NORMALE NORMAL 24 V 50 Hz BO 1115 24 Vac DN 65 80 CN 2010 RADDRIZZATORE Energy Saving RECTIFIER Energy Saving 110 V 50 60 H...