background image

TECHNICAL DATA

•  Use:

not  aggressive  gases  of  the  3  families 

(dry gases)

•  Threaded connections Rp:

(DN 15 ÷ DN 50) according to EN 10226

•  Flanged connections PN 16:

(DN 25 ÷ DN 200) according to ISO 7005

•  On request ANSI 150 fl anged connections

•  Power supply voltage 

 

 

 (see table)

•  Power supply voltage tolerance:

-15% ... +10%

•  Power absorption:

see coils and connector table

•  Max. working pressure:

(DN 15 ÷ DN 50) 200 or 360 mbar

(DN 65 ÷ DN 150)  360 mbar

•  Environment temperature:

-15 ÷ +60 °C

•  Max superfi cial temperature:

85 °C

•  Protection degree:

IP65

•  Class:

   DN 15 ÷ DN 150: A

   DN 200: B

•  Group:

2

•  Closing time:

<1 s

•  Opening time:

<1 s 

Coils: poliammidic resin encapsulated with glass 

fi bre, connection type DIN 43650; the insulation 

class is F (155°) and the enamelled copper wire 

class is H (180°).

Coils (EVP DN 32 ÷ DN 150): the insulation class 

and the enamelled copper wire class is H (180°). 

MATERIALS

• Die-cast aluminium (UNI EN 1706)
• OT-58 brass (UNI EN 12164)
• 11S aluminium (UNI 9002-5)
• galvanized and 430 F stainless steel (UNI EN 

10088)

•  NBR rubber (UNI 7702)
•  nylon 30% glass fi bre 

 

 

(UNI EN ISO 11667)

•  viledon

Summary of Contents for EVP/NC

Page 1: ...ch thermostat etc They can be equipped with a flow regulator and adjustable slow opening kit EC certified according to EN 161 In conformity with the 2009 142 EC Directive Gas Directive In conformity w...

Page 2: ...Environment temperature 15 60 C Max superficial temperature 85 C Protection degree IP65 Class DN 15 DN 150 A DN 200 B Group 2 Closing time 1 s Opening time 1 s Coils poliammidic resin encapsulated wi...

Page 3: ...32 003 110 V 50 Hz EVP05 002 EVP32 002 230 V 50 60 Hz EVP05 008 EVP32 008 EVP NC DN 40 12 Vdc EVP06 001 EVP40 001 24 Vdc EVP06 005 EVP40 005 24 V 50 Hz EVP06 003 EVP40 003 110 V 50 Hz EVP06 002 EVP40...

Page 4: ...spring 4 Body valve 5 Obturator 6 Seal washer 7 G 1 4 cap 8 Filter 9 Fixing screws 10 Cover or bottom 11 Electrical coil 12 Coil fixing nut or screw 13 Flow calibration screw EVPF version 14 Bottom o...

Page 5: ...Capacity diagram EVP NC P max 360 mbar 1 metano 2 aria 3 gas di citt 4 gpl 1 methane 2 air 3 town gas 4 lpg e e ne o...

Page 6: ...cause an explosive atmosphere WARNING all installation wiring maintenance work must be carried out by skilled staff The gas supply must be shut off before installation Check that the line pressure DO...

Page 7: ...on the screw 16 This screw has not limit the opening speed increases gradually screwing clockwise the screw 16 To regulate the rapide stroke operate on the screw 15 Screwing counterclockwise till the...

Page 8: ...ntrol rete pipe r seau red utenza user utilisateur punto de consumo rete pipe r seau red EXAMPLE OF INSTALLATION 2 1 Gas filter type FM 2 Over pressure slam shut off valve type MVB1 MAX 3 Gas pressure...

Page 9: ...seefig 3 4 5 6 unscrew the nut 12 or the slow opening kit 17 and remove the coil 11 Unscrew the fixing screws 9 and with care take the cover 10 off the body 4 of the valve then control the obturator...

Page 10: ...12V RAC ES CN 2110 RADDRIZZATORE Energy Saving RECTIFIER Energy Saving 24 Vdc BO 0417 BO 0417 24V RAC ES CN 2100 NORMALE Energy Saving NORMAL Energy Saving 24 V 50 Hz BO 0417 BO 0417 24V RAC ES CN 21...

Page 11: ...rgy Saving DN 65 DN 80 P max 360 mbar 24 Vdc BO 1110 24 Vdc DN 65 80 CN 2000 NORMALE NORMAL 24 V 50 Hz BO 1115 24 Vac DN 65 80 CN 2010 RADDRIZZATORE Energy Saving RECTIFIER Energy Saving 110 V 50 60 H...

Reviews: