2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
124
List Manual, 09/2017, A5E33842890
Description:
Sets the maximum measuring time for the measuring probe.
If a new pulse is not received before the maximum measuring time has expired, then the speed actual value in r0586
is set to zero. This timer is re-started with the next pulse.
Dependency:
Refer to: r0586
Description:
Sets the BERO gear factor.
The measured speed is multiplied by the BERO gear factor and is displayed in r0586.
Description:
Displays the speed actual value measured using the BERO.
Dependency:
Refer to: p0580, p0583
Note:
For p0580 = 0 (no measuring probe), a value of zero is displayed here.
Description:
Displays the time between the last two BERO pulses.
The measuring time is specified as 32-bit value with a resolution of 1/48 µs.
If a new pulse is not received before the maximum measured time in p0583 expires, then r0587 is set to the
maximum measuring time.
Dependency:
Refer to: p0580
Note:
For p0580 = 0 (no measuring probe), a value of zero is displayed here.
Description:
Displays the number of measuring pulses that have occurred (been received) up until now.
Dependency:
Refer to: p0580
Note:
After reaching 4294967295 (2^32 - 1), the counter starts again at 0.
p0583
Measuring probe maximum measuring time / MT t_meas max
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0.040 [s]
10.000 [s]
10.000 [s]
p0585
Measuring probe gear factor / Probe gear factor
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0.00000 1000.00000
1.00000
r0586
CO: Measuring probe speed actual value / MT n_act
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
p2000
Dyn. index:
-
Unit group:
3_1
Unit selection:
p0505
Func. diagram:
-
Min Max
Factory
setting
- [rpm]
- [rpm]
- [rpm]
r0587
CO: Measuring probe measuring time measured / MT t_meas measured
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
r0588
CO: Measuring probe pulse counter / MT pulse counter
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -