SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
143
2 Parameters
2.2 List of parameters
Description:
Sets the signal source for terminal DI/DO 25.
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
Prerequisite: The DI/DO must be set as an output (p0728.25 = 1).
DI/DO: Bidirectional Digital Input/Output
Description:
Sets the signal source for terminal DI/DO 26.
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
Prerequisite: The DI/DO must be set as an output (p0728.26 = 1).
DI/DO: Bidirectional Digital Input/Output
Description:
Sets the signal source for terminal DI/DO 27.
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
Prerequisite: The DI/DO must be set as an output (p0728.27 = 1).
DI/DO: Bidirectional Digital Input/Output
Description:
Displays the status of digital outputs.
Notice:
Regarding the terminal designation:
The first designation is valid for CU320, the second for CU310.
Note:
Inversion using p0748 has been taken into account.
DI/DO: Bidirectional Digital Input/Output
p0739
BI: CU signal source for terminal DI/DO 25 / CU S_src DI/DO 25
Access level:
1
Calculated:
-
Data type:
U32 / Binary
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2230
Min Max
Factory
setting
- - 0
p0740
BI: CU signal source for terminal DI/DO 26 / CU S_src DI/DO 26
Access level:
1
Calculated:
-
Data type:
U32 / Binary
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2231
Min Max
Factory
setting
- - 0
p0741
BI: CU signal source for terminal DI/DO 27 / CU S_src DI/DO 27
Access level:
1
Calculated:
-
Data type:
U32 / Binary
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2201, 2231
Min Max
Factory
setting
- - 0
r0747
CU digital outputs status / CU DO status
Access level:
1
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2130, 2131, 2132,
2133
Min Max
Factory
setting
- - -
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
DO 0 (NO: T. 19 / NC: T. 18)
High
Low
-
01
DO 1 (NO: T. 21)
High
Low
-
02
DO 2 (NO: T. 24 / NC: T. 23)
High
Low
-
24
DI/DO 24 (T. 51)
High
Low
-
25
DI/DO 25 (T. 52)
High
Low
-
26
DI/DO 26 (T. 53)
High
Low
-
27
DI/DO 27 (T. 54)
High
Low
-