SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
365
2 Parameters
2.2 List of parameters
Description:
Sets the value for fixed value 9 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Description:
Sets the value for fixed value 10 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Description:
Sets the value for fixed value 11 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Description:
Sets the value for fixed value 12 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2209[0...n]
CO: Technology controller fixed value 9 / Tec_ctr fix val 9
CU250S_V (Tech_ctrl)
CU250S_V_CAN
(Tech_ctrl)
CU250S_V_DP
(Tech_ctrl)
CU250S_V_PN
(Tech_ctrl)
Access level:
2
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
PERCENT
Dyn. index:
DDS, p0180
Unit group:
9_1
Unit selection:
p0595
Func. diagram:
7950
Min Max
Factory
setting
-200.00 [%]
200.00 [%]
90.00 [%]
p2210[0...n]
CO: Technology controller fixed value 10 / Tec_ctr fix val 10
CU250S_V (Tech_ctrl)
CU250S_V_CAN
(Tech_ctrl)
CU250S_V_DP
(Tech_ctrl)
CU250S_V_PN
(Tech_ctrl)
Access level:
2
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
PERCENT
Dyn. index:
DDS, p0180
Unit group:
9_1
Unit selection:
p0595
Func. diagram:
7950
Min Max
Factory
setting
-200.00 [%]
200.00 [%]
100.00 [%]
p2211[0...n]
CO: Technology controller fixed value 11 / Tec_ctr fix val 11
CU250S_V (Tech_ctrl)
CU250S_V_CAN
(Tech_ctrl)
CU250S_V_DP
(Tech_ctrl)
CU250S_V_PN
(Tech_ctrl)
Access level:
2
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
PERCENT
Dyn. index:
DDS, p0180
Unit group:
9_1
Unit selection:
p0595
Func. diagram:
7950
Min Max
Factory
setting
-200.00 [%]
200.00 [%]
110.00 [%]
p2212[0...n]
CO: Technology controller fixed value 12 / Tec_ctr fix val 12
CU250S_V (Tech_ctrl)
CU250S_V_CAN
(Tech_ctrl)
CU250S_V_DP
(Tech_ctrl)
CU250S_V_PN
(Tech_ctrl)
Access level:
2
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
PERCENT
Dyn. index:
DDS, p0180
Unit group:
9_1
Unit selection:
p0595
Func. diagram:
7950
Min Max
Factory
setting
-200.00 [%]
200.00 [%]
120.00 [%]