2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
510
List Manual, 09/2017, A5E33842890
Index 1 (sub-index area):
0: 0 ... 255
1: 256 ... 511
2: 512 ... 767
3: 768 ... 1023
Index 2 (parameter area):
0: 1 ... 9999
1: 10000 ... 19999
2: 20000 ... 29999
3: 30000 ... 39999
Index:
[0] = Drive object number
[1] = Sub-index range
[2] = Parameter range
Description:
Sets the drive behavior if a CAN communication error occurs.
Value:
0:
No response
1:
OFF1
2:
OFF2
3:
OFF3
Dependency:
Refer to: F08700
Description:
Displays the register of the CAN controller C_CAN:
Register, Message Interface Register and Message Handler Register - referred to the CAN protocol.
Index:
[0] = Control register
[1] = Status register
[2] = Error counter
[3] = Bit timing register
[4] = Interrupt register
[5] = Test register
[6] = Baud rate prescaler extension register
[7] = Interface 1 command request register
[8] = Interface 1 command mask register
Note:
A description of the individual registers of the C_CAN controller can be taken from "C_CAN User's Manual".
Description:
Sets the CANopen NMT state that is effective after booting.
Value:
4:
Stopped
5:
Operational
127:
Pre-operational
p8641
CAN Abort Connection Option Code / Abort con opt code
CU250S_V_CAN
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 3 3
r8680[0...36]
CAN Diagnosis Hardware / Diagnostics HW
CU250S_V_CAN
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
p8684
CAN NMT state after booting / NMT state aft boot
CU250S_V_CAN
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
4 127
127