2 Parameters
2.2 List of parameters
Description:
Sets the signal source to select a fixed value of the technology controller.
Dependency:
Refer to: p2220, p2222, p2223
Description:
Sets the signal source to select a fixed value of the technology controller.
Dependency:
Refer to: p2220, p2221, p2223
Description:
Sets the signal source to select a fixed value of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222
Description:
Display and connector output for the selected and active fixed value of the technology controller.
Dependency:
Refer to: r2229
Description:
Display and BICO output for the status word of the fixed value selection of the technology controller.
p2221[0...n]
BI: Technology controller fixed value selection bit 1 / Tec_ctrl sel bit 1
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
CDS, p0170
Unit group:
-
Unit selection:
-
Func. diagram:
7950, 7951
Min Max
Factory
setting
- - 0
p2222[0...n]
BI: Technology controller fixed value selection bit 2 / Tec_ctrl sel bit 2
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
CDS, p0170
Unit group:
-
Unit selection:
-
Func. diagram:
7950, 7951
Min Max
Factory
setting
- - 0
p2223[0...n]
BI: Technology controller fixed value selection bit 3 / Tec_ctrl sel bit 3
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
CDS, p0170
Unit group:
-
Unit selection:
-
Func. diagram:
7950, 7951
Min Max
Factory
setting
- - 0
r2224
CO: Technology controller fixed value effective / Tec_ctr FixVal eff
CU250S_V (Tech_ctrl)
CU250S_V_CAN
(Tech_ctrl)
CU250S_V_DP
(Tech_ctrl)
CU250S_V_PN
(Tech_ctrl)
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
PERCENT
Dyn. index:
-
Unit group:
9_1
Unit selection:
p0595
Func. diagram:
7950, 7951
Min Max
Factory
setting
- [%]
- [%]
- [%]
r2225.0
CO/BO: Technology controller fixed value selection status word / Tec_ctr FixVal ZSW
CU250S_V (Tech_ctrl)
CU250S_V_CAN
(Tech_ctrl)
CU250S_V_DP
(Tech_ctrl)
CU250S_V_PN
(Tech_ctrl)
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Technology controller fixed value selected
Yes
No
7950,