SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
39
2 Parameters
2.2 List of parameters
Note:
The following status bits are displayed in r0053:
Bit 00: r1239 Bit 8
Bit 01: r2197 Bit 5 (negated)
Bit 02: r2197 Bit 0 (negated)
Bit 03: r2197 Bit 8
Bit 04: r2197 Bit 2
Bit 05: r2197 Bit 1
Bit 06: r2197 Bit 4
Bit 07: r2197 Bit 9
Bit 08: r2197 Bit 10
Bit 09: r1199 Bit 2 (negated)
Bit 10: r2349 Bit 10
Bit 11: r2349 Bit 11
Description:
Displays control word 1.
Note:
The following control bits are displayed in r0054:
Bit 00: r0898 Bit 0
Bit 01: r0898 Bit 1
Bit 02: r0898 Bit 2
Bit 03: r0898 Bit 3
Bit 04: r0898 Bit 4
Bit 05: r0898 Bit 5
Bit 06: r0898 Bit 6
Bit 07: r2138 Bit 7
Bit 08: r0898 Bit 8
Bit 09: r0898 Bit 9
Bit 10: r0898 Bit 10
Bit 11: r1198 Bit 11
Bit 13: r1198 Bit 13
Bit 14: r1198 Bit 14
Bit 15: r0836 Bit 0
r0054.0...15
CO/BO: Control word 1 / STW 1
Access level:
2
Calculated:
-
Data type:
Unsigned16
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
ON/OFF1
Yes
No
-
01
OC / OFF2
No
Yes
-
02
OC / OFF3
No
Yes
-
03
Enable operation
Yes
No
-
04
Enable ramp-function generator
Yes
No
-
05
Continue ramp-function generator
Yes
No
-
06
Enable speed setpoint
Yes
No
-
07
Acknowledge fault
Yes
No
-
08
Jog bit 0
Yes
No
3030
09
Jog bit 1
Yes
No
3030
10
Master control by PLC
Yes
No
-
11
Direction reversal (setpoint)
Yes
No
-
13
Motorized potentiometer raise
Yes
No
-
14
Motorized potentiometer lower
Yes
No
-
15
CDS bit 0
Yes
No
-