SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
191
2 Parameters
2.2 List of parameters
Recommendation:
Interconnect the signal with main setpoint (p1070).
Dependency:
Refer to: p1070
Note:
For "With ramp-function generator", after an OFF1, OFF2, OFF3 or for a 0 signal via BI: p0852 (inhibit operation,
suppress pulses) the ramp-function generator output (r1050) is set to the starting value (configuration via p1030.0).
Description:
Sets the signal source for the speed limit of the positive direction on the ramp-function generator input.
Note:
The OFF3 ramp-down time (p1135) is effective when the limit is reduced.
Description:
Sets the signal source for the speed limit of the negative direction on the ramp-function generator input.
Note:
The OFF3 ramp-down time (p1135) is effective when the limit is reduced.
Description:
Sets the signal source for jog 1.
Recommendation:
When the setting for this binector input is changed, the motor can only be switched on by means of an appropriate
signal change of the source.
Dependency:
Refer to: p0840, p1058
Notice:
The drive is enabled for jogging using BI: p1055 or BI: p1056.
The command "ON/OFF1" can be issued using BI: p0840 or using BI: p1055/p1056.
Only the signal source that was used to switch on can also be used to switch off again.
Description:
Sets the signal source for jog 1.
Recommendation:
When the setting for this binector input is changed, the motor can only be switched on by means of an appropriate
signal change of the source.
Dependency:
Refer to: p0840, p1058
Notice:
The drive is enabled for jogging using BI: p1055 or BI: p1056.
The command "ON/OFF1" can be issued using BI: p0840 or using BI: p1055/p1056.
Only the signal source that was used to switch on can also be used to switch off again.
p1051[0...n]
CI: Speed limit RFG positive direction of rotation / n_limit RFG pos
Access level:
3
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
T
Scaling:
p2000
Dyn. index:
CDS, p0170
Unit group:
-
Unit selection:
-
Func. diagram:
3050
Min Max
Factory
setting
- - 9733[0]
p1052[0...n]
CI: Speed limit RFG negative direction of rotation / n_limit RFG neg
Access level:
3
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
T
Scaling:
p2000
Dyn. index:
CDS, p0170
Unit group:
-
Unit selection:
-
Func. diagram:
3050
Min Max
Factory
setting
- - 9733[1]
p1055[0...n]
BI: Jog bit 0 / Jog bit 0
CU250S_V_DP
CU250S_V_PN
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
CDS, p0170
Unit group:
-
Unit selection:
-
Func. diagram:
2501, 3030
Min Max
Factory
setting
- - [0]
0
[1] 722.0
[2] 0
[3] 0
p1055[0...n]
BI: Jog bit 0 / Jog bit 0
CU250S_V
CU250S_V_CAN
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
CDS, p0170
Unit group:
-
Unit selection:
-
Func. diagram:
2501, 3030
Min Max
Factory
setting
- - 0