SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
389
2 Parameters
2.2 List of parameters
Note:
DI: Digital Input
If parameter change is rejected, it should be checked whether the input terminal is not already being used in p0488,
p0489, p0493, p0494 or p0580.
Direct measurement via p2517 has a higher priority than measurements via p0488.
Description:
Sets the input terminal for direct measuring probe 2.
After it has been activated via binector input: p2509 = 0/1 signal, the direct measuring probe measures once and can
be used with EPOS.
In order to process signals faster, the direct measuring probe bypasses the handshake technique via the encoder
control word and encoder status word.
Value:
0:
No measuring probe
24:
DI/DO 24 (X208-3)
25:
DI/DO 25 (X208-4)
26:
DI/DO 26 (X208-5)
27:
DI/DO 27 (X208-6)
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Dependency:
Refer to: p0490, p2509, p2510, p2511
Note:
DI: Digital Input
If parameter change is rejected, it should be checked whether the input terminal is not already being used in p0488,
p0489, p0493, p0494 or p0580.
Direct measurement via p2518 has a higher priority than measurements via p0489.
Description:
Sets the behavior of the position actual value preprocessing for the position controller for a DDS changeover.
For p2519 = 1:
In the following cases, for a DDS changeover, the actual position actual value becomes invalid and the reference
point is reset:
- the EDS effective for the closed-loop position control changes.
- the encoder assignment changes (p2502).
- the mechanical relationships change (p2503 ... p2506).
- the direction of rotation changes (p1821).
For absolute encoders, the status of the adjustment (p2507) is also reset if the same absolute encoder remains
selected for the closed-loop position control, but the mechanical relationships or the direction of rotation have
changed.
In the operation state, in addition, a fault (F07494) is generated.
Notice:
The remaining setting values are intended for expanded functionality.
Note:
The behavior for a DDS changeover is determined using the value of p2519 in the target data set.
p2518[0...2]
LR direct measuring probe 2 / Direct MT 2
CU250S_V (Position
control)
CU250S_V_CAN
(Position control)
CU250S_V_DP
(Position control)
CU250S_V_PN
(Position control)
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4010
Min Max
Factory
setting
0 27
0
p2519[0...n]
LR position actual value preprocessing config. DDS changeover / s_act config DDS
CU250S_V (Position
control)
CU250S_V_CAN
(Position control)
CU250S_V_DP
(Position control)
CU250S_V_PN
(Position control)
Access level:
4
Calculated:
-
Data type:
Integer16
Can be changed:
U, T
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 5 1