2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
396
List Manual, 09/2017, A5E33842890
Description:
Setting to activate the integral time of the position controller.
Value = 0 ms --> The I component of the position controller is deactivated.
Dependency:
Refer to: p2538, r2559, p2731
Notice:
The effectiveness of the I component corresponding to the set integral time depends on binector input p2731.
Description:
Setting and connector output for the speed limit of the position controller output.
Dependency:
Refer to: p2541
Description:
Sets the signal source for the position controller output limit.
Dependency:
Refer to: p2540
Description:
Sets the standstill window for the standstill monitoring function.
After the standstill monitoring time expires, it is cyclically checked whether the difference between the setpoint and
actual position is located within the standstill window and, if required, an appropriate fault is output.
Value = 0 --> The standstill monitoring is deactivated.
Dependency:
Refer to: p2543, p2544
Refer to: F07450
Note:
The following applies for the setting of the standstill and positioning window:
Standstill window (p2542) >= positioning window (p2544)
p2539[0...n]
LR integral time / Tn
CU250S_V (Position
control)
CU250S_V_CAN
(Position control)
CU250S_V_DP
(Position control)
CU250S_V_PN
(Position control)
Access level:
1
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
-
Unit selection:
-
Func. diagram:
4015
Min Max
Factory
setting
0.00 [ms]
100000.00 [ms]
0.00 [ms]
p2540
CO: LR position controller output speed limit / LR_outp n_lim
CU250S_V (Position
control)
CU250S_V_CAN
(Position control)
CU250S_V_DP
(Position control)
CU250S_V_PN
(Position control)
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
p2000
Dyn. index:
-
Unit group:
3_1
Unit selection:
p0505
Func. diagram:
4015
Min Max
Factory
setting
0.000 [rpm]
210000.000 [rpm]
210000.000 [rpm]
p2541
CI: LR position controller output speed limit signal source / LR_out n_lim S_src
CU250S_V (Position
control)
CU250S_V_CAN
(Position control)
CU250S_V_DP
(Position control)
CU250S_V_PN
(Position control)
Access level:
1
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
T
Scaling:
p2000
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4015
Min Max
Factory
setting
- - 2540[0]
p2542
LR standstill window / Standstill window
CU250S_V (Position
control)
CU250S_V_CAN
(Position control)
CU250S_V_DP
(Position control)
CU250S_V_PN
(Position control)
Access level:
1
Calculated:
-
Data type:
Unsigned32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4020
Min Max
Factory
setting
0 [LU]
2147483647 [LU]
200 [LU]