2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
262
List Manual, 09/2017, A5E33842890
Note:
Only active when the "moment of inertia estimator" function module is active (r0108.10 = 1) and p1400.18 =1.
For operation with encoder, p1400.23 must also be set to 1.
Description:
Sets the signal source for the torque setpoint for torque control.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1), "Dynamic Drive Control" (DDC, p0096
= 2)
Note:
A change is made to closed-loop torque control if, in p1300, closed-loop torque control was selected or if the
selection was made using the changeover source in p1501.
it is also possible to change over in operation using p1501.
Description:
Displays the torque setpoint before entering the supplementary torque.
For closed-loop speed control, r1508 corresponds to the speed controller output; for closed-loop torque control,
r1508 corresponds to the torque setpoint of the signal source assigned in p1503.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Description:
Sets the signal source for supplementary torque 1.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Description:
Sets the signal source for scaling the supplementary torque 1.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Description:
Sets the signal source for supplementary torque 2.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
p1503[0...n]
CI: Torque setpoint / M_set
Access level:
3
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
T
Scaling:
p2003
Dyn. index:
CDS, p0170
Unit group:
-
Unit selection:
-
Func. diagram:
6020, 6060
Min Max
Factory
setting
- - 0
r1508
CO: Torque setpoint before supplementary torque / M_set bef. M_suppl
Access level:
2
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
p2003
Dyn. index:
-
Unit group:
7_1
Unit selection:
p0505
Func. diagram:
6030, 6060, 6722
Min Max
Factory
setting
- [Nm]
- [Nm]
- [Nm]
p1511[0...n]
CI: Supplementary torque 1 / M_suppl 1
Access level:
3
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
T
Scaling:
p2003
Dyn. index:
CDS, p0170
Unit group:
-
Unit selection:
-
Func. diagram:
6020, 6060
Min Max
Factory
setting
- - 0
p1512[0...n]
CI: Supplementary torque 1 scaling / M_suppl 1 scal
Access level:
3
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
T
Scaling:
PERCENT
Dyn. index:
CDS, p0170
Unit group:
-
Unit selection:
-
Func. diagram:
5060, 6060
Min Max
Factory
setting
- - 0
p1513[0...n]
CI: Supplementary torque 2 / M_suppl 2
Access level:
3
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
T
Scaling:
p2003
Dyn. index:
CDS, p0170
Unit group:
-
Unit selection:
-
Func. diagram:
6020, 6060
Min Max
Factory
setting
- - 0