2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
84
List Manual, 09/2017, A5E33842890
Description:
Settings for the basic encoder properties.
Notice:
This parameter is automatically pre-set for encoders from the encoder list (p0400).
When selecting a catalog encoder, this parameter cannot be changed (write protection). Information in p0400 should
be carefully observed when removing write protection.
Note:
ZM: Zero mark
SMC: Sensor Module Cabinet
If a technique to determine the commutation information/data has not been selected (e.g. track C/D, Hall sensor), and
the encoder pulse number is an integer multiple of the pole number, then the following applies:
The track A/B is adjusted to match the magnetic position of the motor.
For bit 01, 02 (absolute encoder, multiturn encoder):
These bits can only be selected for EnDat encoders, SSI encoders or DRIVE-CLiQ encoders.
For bit 10 (DRIVE-CLiQ encoder):
This bit is only used for the large-scale integrated DRIVE-CLiQ encoders that provide their encoder data directly in
DRIVE-CLiQ format without converting this data. This bit is not, therefore, set for first-generation DRIVE-CLiQ
encoders.
For bit 12 (equidistant zero mark):
The zero marks occur at regular intervals (e.g. rotary encoder with 1 zero mark per revolution or linear encoder with
constant zero mark distance).
The bit activates monitoring of the zero mark distance (p0424/p0425, linear/rotary) or in the case of the linear
encoder with 1 zero mark and p0424 = 0 zero mark monitoring is activated.
For bit 13 (irregular zero mark):
The zero marks occur at irregular intervals (e.g. a linear scale with only 1 zero mark in the traversing range). The zero
mark distance is not monitored.
For bit 14 (distance-coded zero mark):
The distance (clearance) between two or several consecutive zero marks allows the absolute position to be
calculated.
For bit 15 (commutation with zero mark):
Only applicable for synchronous motors.
The function can be de-selected by priority via p0430.23.
p0404[0...n]
Encoder configuration effective / Enc_config eff
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
C(4)
Scaling:
-
Dyn. index:
EDS, p0140
Unit group:
-
Unit selection:
-
Func. diagram:
4010, 4704
Min Max
Factory
setting
-
-
0000 0000 0000 0000 0000 0000 0000
0000 bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Linear encoder
Yes
No
-
01
Absolute encoder
Yes
No
-
02
Multiturn encoder
Yes
No
-
03
Track A/B square-wave
Yes
No
-
04
Track A/B sine
Yes
No
-
05
Track C/D
Yes
No
-
06
Hall sensor
Yes
No
-
08
EnDat encoder
Yes
No
-
09
SSI encoder
Yes
No
-
10
DRIVE-CLiQ encoder
Yes
No
-
11
Digital encoder
Yes
No
-
12
Equidistant zero mark
Yes
No
-
13
Irregular zero mark
Yes
No
-
14
Distance-coded zero mark
Yes
No
-
15
Commutation with zero mark (not ASM)
Yes
No
-
16
Acceleration
Yes
No
-
17
Track A/B analog
Yes
No
-
20
Voltage level 5 V
Yes
No
-
21
Voltage level 24 V
Yes
No
-
22
Remote sense (only SMC30)
Yes
No
-
23
Resolver excitation
Yes
No
-