SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
725
2 Parameters
2.6 Quick commissioning (p0010 = 1)
If p0010 = 1 is selected, p0003 (user access level) can be used to select the parameters that
are to be accessed.
At the end of the quick commissioning, set p3900 = 1 to perform the required motor
calculations and reset all other parameters (not included in p0010 = 1) to their default settings.
p1300
Open-loop/closed-loop control operating mode
2
C(1)T
p1500
Torque setpoint selection
2
C(1)T
p1900
Motor data identification and rotating measurement 1
C(1)T
p1905
Parameter tuning selection
1
C(1)T
p2196
Torque utilization scaling
1
C(1,3)UT
p3900
Completion of quick commissioning
1
C(1)
Note
This only applies for the quick commissioning.
Table 2-7
Quick commissioning (p0010 = 1), continued
Par. no.
Name
Access level
Can be
changed