2 Parameters
2.4 BICO parameters (connectors/binectors)
SINAMICS G120 CU250S-2 Control Units
716
List Manual, 09/2017, A5E33842890
r0069[0...8]
CO: Phase current actual value / I_phase act val
r0070
CO: Actual DC link voltage / Vdc act val
r0072
CO: Output voltage / U_output
r0074
CO: Modulat_depth / Mod_depth
r0075
CO: Current setpoint field-generating / Id_set
r0076
CO: Current actual value field-generating / Id_act
r0077
CO: Current setpoint torque-generating / Iq_set
r0078
CO: Current actual value torque-generating / Iq_act
r0079
CO: Torque setpoint / M_set
r0080[0...1]
CO: Torque actual value / Actual torque
r0081
CO: Torque utilization / M_Utilization
r0082[0...2]
CO: Active power actual value / P_act
r0083
CO: Flux setpoint / Flex setp
r0084[0...1]
CO: Flux actual value / Flux act val
r0087
CO: Actual power factor / Cos phi act
r0094
CO: Transformation angle / Transformat_angle
r0289
CO: Maximum power unit output current / PU I_outp max
r0477[0...2]
CO: Measuring gear position difference / Meas gear pos diff
r0479[0...2]
CO: Diagnostics encoder position actual value Gn_XIST1 / Diag Gn_XIST1
r0481[0...2]
CO: Encoder status word Gn_ZSW / Enc Gn_ZSW
r0482[0...2]
CO: Encoder actual position value Gn_XIST1 / Enc Gn_XIST1
r0483[0...2]
CO: Encoder actual position value Gn_XIST2 / Enc Gn_XIST2
r0485[0...2]
CO: Measuring gear encoder raw value incremental / Enc raw val incr
r0486[0...2]
CO: Measuring gear encoder raw value absolute / Enc raw val abs
r0497[0...2]
CO: Encoder diagnostic signal double word / Enc diag DW
r0498[0...2]
CO: Encoder diagnostic signal low word / Enc diag low word
r0499[0...2]
CO: Encoder diagnostic signal high word / Enc diag high word
r0586
CO: Measuring probe speed actual value / MT n_act
r0587
CO: Measuring probe measuring time measured / MT t_meas measured
r0588
CO: Measuring probe pulse counter / MT pulse counter
r0752[0...1]
CO: CU analog inputs input voltage/current actual / CU AI U/I_inp act
r0755[0...1]
CO: CU analog inputs actual value in percent / CU AI value in %
p0791[0...1]
CO: Fieldbus analog outputs / Fieldbus AO
r0944
CO: Counter for fault buffer changes / Fault buff change
p1001[0...n]
CO: Fixed speed setpoint 1 / n_set_fixed 1
p1002[0...n]
CO: Fixed speed setpoint 2 / n_set_fixed 2
p1003[0...n]
CO: Fixed speed setpoint 3 / n_set_fixed 3
p1004[0...n]
CO: Fixed speed setpoint 4 / n_set_fixed 4
p1005[0...n]
CO: Fixed speed setpoint 5 / n_set_fixed 5
p1006[0...n]
CO: Fixed speed setpoint 6 / n_set_fixed 6
p1007[0...n]
CO: Fixed speed setpoint 7 / n_set_fixed 7
p1008[0...n]
CO: Fixed speed setpoint 8 / n_set_fixed 8
p1009[0...n]
CO: Fixed speed setpoint 9 / n_set_fixed 9
p1010[0...n]
CO: Fixed speed setpoint 10 / n_set_fixed 10
p1011[0...n]
CO: Fixed speed setpoint 11 / n_set_fixed 11
p1012[0...n]
CO: Fixed speed setpoint 12 / n_set_fixed 12
p1013[0...n]
CO: Fixed speed setpoint 13 / n_set_fixed 13
p1014[0...n]
CO: Fixed speed setpoint 14 / n_set_fixed 14
p1015[0...n]
CO: Fixed speed setpoint 15 / n_set_fixed 15
r1024
CO: Fixed speed setpoint effective / Speed fixed setp
r1045
CO: Mot. potentiometer speed setp. in front of ramp-fct. gen. / Mop n_set bef RFG
r1050
CO: Motorized potentiometer setpoint after ramp-function generator / Mot poti setpoint
r1073
CO: Main setpoint effective / Main setpoint eff
r1077
CO: Supplementary setpoint effective / Suppl setpoint eff
r1078
CO: Total setpoint effective / Total setpoint eff