2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
388
List Manual, 09/2017, A5E33842890
Description:
Sets the signal source for the setting value of the function "setting position actual value".
Index:
[0] = Position control
[1] = Encoder 1
[2] = Encoder 2
[3] = Reserved
Dependency:
Refer to: p2502, p2514
Description:
Sets the signal source for the position offset.
Index:
[0] = Position control
[1] = Encoder 1
[2] = Encoder 2
[3] = Reserved
Dependency:
Refer to: p2502, r2667
Description:
Sets the input terminal for direct measuring probe 1.
After it has been activated via binector input: p2509 = 0/1 signal, the direct measuring probe measures once and can
be used with EPOS.
In order to process signals faster, the direct measuring probe bypasses the handshake technique via the encoder
control word and encoder status word.
Value:
0:
No measuring probe
24:
DI/DO 24 (X208-3)
25:
DI/DO 25 (X208-4)
26:
DI/DO 26 (X208-5)
27:
DI/DO 27 (X208-6)
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Dependency:
Refer to: p0490, p2509, p2510, p2511
p2515[0...3]
CI: LR position actual setting setting value / s_act set setVal
CU250S_V (Position
control)
CU250S_V_CAN
(Position control)
CU250S_V_DP
(Position control)
CU250S_V_PN
(Position control)
Access level:
1
Calculated:
-
Data type:
U32 / Integer32
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4010
Min Max
Factory
setting
- - 0
p2516[0...3]
CI: LR position offset / Position offset
CU250S_V (Position
control)
CU250S_V_CAN
(Position control)
CU250S_V_DP
(Position control)
CU250S_V_PN
(Position control)
Access level:
1
Calculated:
-
Data type:
U32 / Integer32
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4010
Min Max
Factory
setting
- - [0]
2667[0]
[1] 0
[2] 0
[3] 0
p2517[0...2]
LR direct measuring probe 1 / Direct MT 1
CU250S_V (Position
control)
CU250S_V_CAN
(Position control)
CU250S_V_DP
(Position control)
CU250S_V_PN
(Position control)
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4010
Min Max
Factory
setting
0 27
0