Dependency:
For 1LA7 motors (p0300), the parameter is pre-set as a function of p0307 and p0311.
Refer to: p0625
Notice:
When selecting a standard induction motor listed in the catalog (p0300 > 100, p0301 > 10000), this parameter is
automatically pre-assigned and is write protected. Information in p0300 should be carefully observed when removing
write protection.
Note:
When quick commissioning is exited with p3900 > 0, then the parameter is reset if a catalog motor has not been
selected (p0300).
The signal is not suitable as a process quantity and may only be used as a display quantity.
Description:
Defines the rated overtemperature of the squirrel cage rotor referred to ambient temperature in the motor
temperature model 2 (p0612.1 = 1).
Dependency:
For 1LA7 motors (p0300), the parameter is pre-set as a function of p0307 and p0311.
Refer to: p0625
Notice:
When selecting a standard induction motor listed in the catalog (p0300 > 100, p0301 > 10000), this parameter is
automatically pre-assigned and is write protected. Information in p0300 should be carefully observed when removing
write protection.
Note:
When quick commissioning is exited with p3900 > 0, then the parameter is reset if a catalog motor has not been
selected (p0300).
Description:
Displays the ambient temperature of the motor temperature model (models 2 and 3).
Description:
Displays the stator iron temperature of the motor temperature model (models 2 and 3).
Note:
For motor temperature model 1 (p0612.0 = 1), this parameter is not valid:
Description:
Displays the stator winding temperature of the motor temperature model.
Dependency:
Refer to: F07011, A07012, A07910
p0628[0...n]
Motor overtemperature rotor / Mot T_over rotor
Access level:
4
Calculated:
p0340 = 1,2
Data type:
FloatingPoint32
Can be changed:
C(3), U, T
Scaling:
-
Dyn. index:
MDS
Unit group:
21_2
Unit selection:
p0505
Func. diagram:
8018
Min Max
Factory
setting
20 [K]
200 [K]
100 [K]
r0630[0...n]
Mot_temp_mod ambient temperature / Mod T_ambient
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
p2006
Dyn. index:
MDS
Unit group:
21_1
Unit selection:
p0505
Func. diagram:
8018
Min Max
Factory
setting
- [°C]
- [°C]
- [°C]
r0631[0...n]
Mot_temp_mod stator iron temperature / Mod T_stator
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
p2006
Dyn. index:
MDS
Unit group:
21_1
Unit selection:
p0505
Func. diagram:
8018
Min Max
Factory
setting
- [°C]
- [°C]
- [°C]
r0632[0...n]
Mot_temp_mod stator winding temperature / Mod T_winding
Access level:
2
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
p2006
Dyn. index:
MDS
Unit group:
21_1
Unit selection:
p0505
Func. diagram:
8017, 8018
Min Max
Factory
setting
- [°C]
- [°C]
- [°C]