SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
539
2 Parameters
2.2 List of parameters
Description:
Sets the component number for a component to get its status LED to flash.
Dependency:
Refer to: p9211
Description:
Sets the function for the component selected in p9210.
After initiating a function, the parameter is automatically reset again.
Example:
- set the component number (p9210).
- select the "flashing on" function (set p9211 = 1).
Value:
-1:
Select function
0:
Flashing off
1:
Flashing on
Dependency:
Refer to: p9210
Notice:
If a task cannot be executed (e.g. the component number in p9210 does not exist), the following applies:
- there is no negative feedback signal.
- the value is reset anyway.
Description:
Sets the enable signals for the safe motion monitoring.
Dependency:
Refer to: p9501
Refer to: F01682, F01683
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
A change only becomes effective after a POWER ON.
For bit 30 = 1, PROFIsafe telegram 900 must be configured in the F host.
SDI: Safe Direction (safe motion direction)
SLS: Safely Limited Speed
SSM: Safe Speed Monitor (safety-relevant feedback signal from the speed monitoring)
p9210
Flashing component number / Flash comp_no.
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 499
0
p9211
Flash function / Flash fct.
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
-1 1 -1
p9301
SI Motion enable safety functions (processor 2) / SI Mtn enable P2
CU250S_V_DP
CU250S_V_PN
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
-
-
0000 0000 0000 0000 0000 0000 0000
0000 bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Enable SI Motion
Enable
Inhibit
-
16
Enable SSM hysteresis and filtering
Enable
Inhibit
2823
17
Enable SDI
Enable
Inhibit
2824
30
Enable F-DI in PROFIsafe telegram 900
Enable
Inhibit
-