SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
177
2 Parameters
2.2 List of parameters
To check the reset operation:
After the drive unit has been restarted and communications have been established, read p0972 and check the
following:
p0972 = 0? --> the reset was successfully executed.
p0972 = 0? --> the reset was not executed.
Description:
Displays the actual position encoder used according to PROFIdrive.
Index:
[0] = Header
[1] = Type encoder 1
[2] = Resolution encoder 1
[3] = Shift factor G1_XIST1
[4] = Shift factor G1_XIST2
[5] = Distinguishable revolutions encoder 1
[6...10] = Reserved
[11] = Type encoder 2
[12] = Resolution encoder 2
[13] = Shift factor G2_XIST1
[14] = Shift factor G2_XIST2
[15] = Distinguishable revolutions encoder 2
[16...30] = Reserved
Note:
Information about the individual indices can be taken from the following literature:
PROFIdrive Profile Drive Technology
Description:
Displays the parameters that exist for this drive.
Dependency:
Refer to: r0981, r0989
Note:
Modified parameters are displayed in indices 0 to 298. If an index contains the value 0, then the list ends here. In a
long list, index 299 contains the parameter number at which position the list continues.
This list consists solely of the following parameters:
r0980[0...299], r0981[0...299] ... r0989[0...299]
The parameters in this list are not displayed in the expert list of the commissioning software. However, they can be
read from a higher-level control system (e.g. PROFIBUS master).
r0979[0...30]
PROFIdrive encoder format / PD encoder format
CU250S_V
CU250S_V (Position
control)
CU250S_V_CAN
CU250S_V_CAN
(Position control)
CU250S_V_DP
CU250S_V_DP
(Position control)
CU250S_V_PN
CU250S_V_PN
(Position control)
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4704
Min Max
Factory
setting
- - -
r0980[0...299]
List of existing parameters 1 / List avail par 1