SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
483
2 Parameters
2.2 List of parameters
Description:
Sets the linear coefficients for moment of inertia precontrol in the positive direction when the moment of inertia
estimator is active.
The estimated moment of inertia is obtained according to the following formula:
Moment of inertia (J) = linear coefficient (p5312) * load constant coefficient (p5313)
Dependency:
The function module "Moment of inertia estimator" (r0108.10) must be activated for the "Moment of inertia precontrol"
function.
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Refer to: p5310, r5311, p5313, p5314, p5315
Description:
Sets of the constant coefficients for moment of inertia precontrol in the positive direction when the moment of inertia
estimator is active.
The estimated moment of inertia is obtained according to the following formula:
Moment of inertia (J) = linear coefficient (p5312) * load constant coefficient (p5313)
Dependency:
The function module "Moment of inertia estimator" (r0108.10) must be activated for the "Moment of inertia precontrol"
function.
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Refer to: p5310, r5311, p5312, p5314, p5315
Description:
Sets the linear coefficients for moment of inertia precontrol in the negative direction when the moment of inertia
estimator is active.
The estimated moment of inertia is obtained according to the following formula:
Moment of inertia (J) = linear coefficient (p5314) * load constant coefficient (p5315)
Dependency:
The function module "Moment of inertia estimator" (r0108.10) must be activated for the "Moment of inertia precontrol"
function.
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Refer to: p5310, r5311, p5312, p5313, p5315
p5312[0...n]
Moment of inertia precontrol linear positive / J_est lin pos
Access level:
3
Calculated:
p0340 = 1
Data type:
FloatingPoint32
Can be changed:
C(3), U, T
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
-340.28235E36 [s²]
340.28235E36 [s²]
0.000000 [s²]
p5313[0...n]
Moment of inertia precontrol constant positive / J_est const pos
Access level:
3
Calculated:
p0340 = 1
Data type:
FloatingPoint32
Can be changed:
C(3), U, T
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
25_1
Unit selection:
p0100
Func. diagram:
-
Min Max
Factory
setting
-340.28235E36 [kgm²]
340.28235E36 [kgm²]
0.000000 [kgm²]
p5314[0...n]
Moment of inertia precontrol linear negative / J_est lin neg
Access level:
3
Calculated:
p0340 = 1
Data type:
FloatingPoint32
Can be changed:
C(3), U, T
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
-340.28235E36 [s²]
340.28235E36 [s²]
0.000000 [s²]