2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
414
List Manual, 09/2017, A5E33842890
Description:
Sets the reference point offset for search for reference.
Dependency:
Refer to: p2598
Description:
Sets the inner window for flying referencing.
Value = 0:
The evaluation of the inner window is deactivated.
Dependency:
Refer to: p2597, p2602, r2684
Notice:
The inner window must be set so that it is smaller than the outer window.
Note:
If the difference between the reference point coordinate and detected actual position is less than the inner window,
then no correction is executed for a referenced axis.
If the difference between the reference point coordinate and detected actual position is greater than the inner window
and less than the outer window (p2602), then a correction is executed for a referenced axis.
Description:
Sets the outer window for flying referencing.
Value = 0:
The evaluation of the outer window is deactivated.
Dependency:
Refer to: p2597, r2684
Refer to: A07489
Notice:
The inner window must be set so that it is smaller than the outer window.
Note:
If the difference between the reference point coordinate and detected actual position is greater than the outer
window, then no correction is executed for the referenced axis. Further, an appropriate message is output and
r2684.3 is set to 1.
p2600
EPOS search for reference reference point offset / Ref_pt offset
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
Integer32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3612
Min Max
Factory
setting
-2147482648 [LU]
2147482647 [LU]
0 [LU]
p2601
EPOS flying referencing inner window / Inner window
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
Integer32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3614
Min Max
Factory
setting
0 [LU]
2147482647 [LU]
0 [LU]
p2602
EPOS flying referencing outer window / Outer window
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
Integer32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3614
Min Max
Factory
setting
0 [LU]
2147482647 [LU]
0 [LU]