2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
170
List Manual, 09/2017, A5E33842890
Description:
Display and BICO output for the status word of the sequence control.
Note:
For bits 00, 01, 02, 04, 05, 06, 09:
For PROFIdrive, these signals are used for status word 1.
For bit 13:
When the "Safe Brake Control" (SBC) is activated and selected, the brake is no longer controlled using this signal.
For bit 14, 15:
These signals are only of significance when the "extended brake control" function module is activated (r0108.14 = 1).
Description:
Displays or sets the PROFIBUS address for PROFIBUS interface on the Control Unit.
The address can be set as follows:
1) Using the DIP switch on the Control Unit.
--> p0918 can then only be read and displays the selected address.
--> A change only becomes effective after a POWER ON.
2) Using p0918
--> Only if all of the DIP switches are set to ON or OFF.
--> The address is saved in a non-volatile fashion using the function "copy from RAM to ROM".
--> A change only becomes effective after a POWER ON.
Note:
Permissible PROFIBUS addresses: 1 ... 126
Address 126 is used for commissioning.
Every PROFIBUS address change only becomes effective after a POWER ON.
r0899.0...15
CO/BO: Status word sequence control / ZSW seq_ctrl
Access level:
2
Calculated:
-
Data type:
Unsigned16
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2503
Min Max
Factory
setting
- - -
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Ready for switching on
Yes
No
-
01
Ready
Yes
No
-
02
Operation enabled
Yes
No
-
03
Jog active
Yes
No
-
04
No coasting active
OFF2 inactive
OFF2 active
-
05
No Quick Stop active
OFF3 inactive
OFF3 active
-
06
Switching-on inhibited active
Yes
No
-
07
Drive ready
Yes
No
-
08
Controller enable
Yes
No
-
09
Control request
Yes
No
-
11
Pulses enabled
Yes
No
-
12
Open holding brake
Yes
No
-
13
Command close holding brake
Yes
No
-
14
Pulse enable from the brake control
Yes
No
-
15
Setpoint enable from the brake control
Yes
No
-
p0918
PROFIBUS address / PB address
CU250S_V_DP
Access level:
2
Calculated:
-
Data type:
Unsigned16
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2401, 2410
Min Max
Factory
setting
1 126
126