2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
398
List Manual, 09/2017, A5E33842890
Description:
Sets the tolerance for the dynamic following error monitoring.
If the dynamic following error (r2563) exceeds the selected tolerance, then an appropriate fault is output.
Value = 0 --> The dynamic following error monitoring is deactivated.
Dependency:
Refer to: r2563, r2684
Refer to: F07452
Note:
The tolerance bandwidth is intended to prevent the dynamic following error monitoring incorrectly responding due to
operational control sequences (e.g. during load surges).
Description:
Sets the cam switching position 1.
Dependency:
Refer to: p2548, r2683
Caution:
Only after the axis has been referenced can it be guaranteed that the cam switching signals when output have a
"true" position reference.
Note:
Position actual value <= cam switching position 1 --> r2683.8 = 1 signal
Position actual value > cam switching position 1 --> r2683.8 = 0 signal
Description:
Sets the cam switching position 2.
Dependency:
Refer to: p2547, r2683
Caution:
Only after the axis has been referenced can it be guaranteed that the cam switching signals when output have a
"true" position reference.
Note:
Position actual value <= cam switching position 2 --> r2683.9 = 1 signal
Position actual value > cam switching position 2 --> r2683.9 = 0 signal
p2546[0...n]
LR dynamic following error monitoring tolerance / s_delta_monit tol
CU250S_V (Position
control)
CU250S_V_CAN
(Position control)
CU250S_V_DP
(Position control)
CU250S_V_PN
(Position control)
Access level:
1
Calculated:
-
Data type:
Unsigned32
Can be changed:
U, T
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
-
Unit selection:
-
Func. diagram:
4025
Min Max
Factory
setting
0 [LU]
2147483647 [LU]
1000 [LU]
p2547
LR cam switching position 1 / Cam position 1
CU250S_V (Position
control)
CU250S_V_CAN
(Position control)
CU250S_V_DP
(Position control)
CU250S_V_PN
(Position control)
Access level:
1
Calculated:
-
Data type:
Integer32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4025
Min Max
Factory
setting
-2147483648 [LU]
2147483647 [LU]
0 [LU]
p2548
LR cam switching position 2 / Cam position 2
CU250S_V (Position
control)
CU250S_V_CAN
(Position control)
CU250S_V_DP
(Position control)
CU250S_V_PN
(Position control)
Access level:
1
Calculated:
-
Data type:
Integer32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4025
Min Max
Factory
setting
-2147483648 [LU]
2147483647 [LU]
0 [LU]