2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
418
List Manual, 09/2017, A5E33842890
Description:
Sets the maximum number of traversing blocks that are available.
Dependency:
Refer to: p2616, p2617, p2618, p2619, p2620, p2621, p2622, p2623, p2624
Description:
Sets a block number.
-1: Invalid block number. These blocks are not taken into account.
0 ... 15: valid block number.
Dependency:
The number of indices depends on p2615.
Refer to: p2615, p2617, p2618, p2619, p2620, p2621, p2622, p2623, p2624
Description:
Sets the target position for the traversing block.
Dependency:
The number of indices depends on p2615.
Refer to: p2615, p2616, p2618, p2619, p2620, p2621, p2622, p2623, p2624
Note:
The target position is approached in either relative or absolute terms depending on p2623.
Description:
Sets the velocity for the traversing block.
Dependency:
The number of indices depends on p2615.
Refer to: p2615, p2616, p2617, p2619, p2620, p2621, p2622, p2623, p2624, p2646
Note:
The velocity can be influenced using the velocity override (p2646).
p2615
EPOS maximum number of traversing blocks / Trav_block qty max
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
Unsigned8
Can be changed:
C(17)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3616
Min Max
Factory
setting
1 16
16
p2616[0...n]
EPOS traversing block block number / Trav_blk, blkNo.
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
Integer16
Can be changed:
U, T
Scaling:
-
Dyn. index:
p2615
Unit group:
-
Unit selection:
-
Func. diagram:
3616
Min Max
Factory
setting
-1 15
-1
p2617[0...n]
EPOS traversing block position / Trav_block pos
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
Integer32
Can be changed:
U, T
Scaling:
-
Dyn. index:
p2615
Unit group:
-
Unit selection:
-
Func. diagram:
3616
Min Max
Factory
setting
-2147482648 [LU]
2147482647 [LU]
0 [LU]
p2618[0...n]
EPOS traversing block velocity / Trav_block v
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
Integer32
Can be changed:
U, T
Scaling:
-
Dyn. index:
p2615
Unit group:
-
Unit selection:
-
Func. diagram:
3616
Min Max
Factory
setting
1 [1000 LU/min]
40000000 [1000 LU/min]
600 [1000 LU/min]