Temp/Set (80°F - 104°F / 26°C - 40°C)

The start-up temperature is set at 100F°/37°C.  The last 
measured temperature is constantly displayed on the LCD.

Note that the last measured spa temperature displayed is 
current only when the pump has been running for at least 
2 minutes.

To display the set temperature, press the “Temp” or “Set” 
pad once.

To change the set temperature, press the pad a second time 
before the LCD stops flashing.  Each press of the “Temp” or “Set” 
pad will continue to either raise or lower the set temperature.

If the opposite direction is desired, release the pad and let the 
display revert to the current water temperature.  Press the pad to 
display the set temperature, and again to make the temperature 
change in the desired direction.

After three seconds, the LCD will stop flashing and display the 
current spa temperature.

Note: If there is not a blower on the system, an alternate panel with 
separate "Up" and "Down" buttons in place of a "Set" or "Temp" button 
may be used.  Simply press "Up" or "Down" where a "Temp" or "Set" 
button press is indicated.  (Ignore the "direction reversal paragraph.")

Jets 1

Touch the “Jets 1” button once to activate the low speed of the 
pump and again for the high speed.  Press the “Jets 1” button 
again to turn off the pump.  If left running, the low speed of 
the pump will automatically turn off after 4 hours, and the high 
speed will automatically turn off after 15 minutes.  The low 
speed of the pump may activate for at least 2 minutes every 30 
minutes to detect the spa temperature and then to heat to the set 
temperature if needed, depending upon mode.  When the low 
speed turns on automatically, it cannot be deactivated from the 
panel; however, the high speed may be started.

Jets 2

Touch the “Jets 2” button once to activate the low speed of the 
pump and again for the high speed.  Press the “Jets 2” button 
again to turn off the pump.  If left running, the pump will 
automatically turn off after 15 minutes.

Light

Press the “Light” button to turn the light on and off.  If left on, 
the light automatically turns off after 4 hours.

(over)

MVP240 Reference Card for VS511/GS511

Non-Circ Operation

Initial Start-up

When your spa is first actuated, it will go into Priming mode, indicated by “

.”

Please see the M-7 Installation Instruction Manual 

for complete instructions on Power-up and Pump Priming

.  

The Priming mode will last for less than 5 minutes (press "Temp" or 

"Set" to skip Priming Mode) and then the spa will begin to heat and maintain the water temperature in the Standard mode.

Mode

Mode is changed by pressing the “Temp” or “Set” button, then 
pressing the “Light” button.

Standard Mode

 is programmed to maintain the desired 

temperature.  Note that the last measured spa temperature 
displayed is current only when the pump has been running for at 
least 2 minutes.  “

” will be displayed momentarily when you 

switch into Standard Mode.

Economy Mode

 heats the spa to the set temperature only 

during filter cycles.  “

” will display solid when temperature 

is not current, and will alternate with temperature when 
temperature is current.

Sleep Mode 

heats the spa to within 20°F/10°C of the set 

temperature only during filter cycles.  “

” will display solid 

when temperature is not current, and will alternate with 
temperature when temperature is current.

Preset Filter Cycles

The first filter cycle begins 6 minutes after the spa is energized.  
The second filter cycle begins 12 hours later.  Filter duration is 
programmable for 2, 4, 6, 8 hours or for continuous filtration 
(indicated by “

”).  The default filter time is 2 hours.

To program, press “Temp” or “Set,” then “Jets 1.”  Press “Temp” 
or “Set” to adjust.  Press “Jets 1” to exit programming.

The blower purges for 30 seconds at the beginning of each filter 
cycle.  The low speed of the pump runs during filtration and the 
ozone generator (if installed) will be enabled.

Freeze Protection

If the temperature sensors detect a drop to below 44°F/6.7°C 
within the heater, the pump and blower will automatically 
activate to provide freeze protection.  The equipment stays on 
until 4 minutes after the sensors detect that the spa temperature 
has risen to 45°F/7.2°C or higher.  In colder climates, an 
optional additional freeze sensor may be added to protect against 
freeze conditions that may not be sensed by the standard sensors.  
Aux freeze sensor protection acts similarly except with the 
temperature thresholds determined by the switch and without a 
4-minute delay in turnoff.  See your dealer for details.

Jets 2

Light

Jets 1

Temp