SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
287
2 Parameters
2.2 List of parameters
Description:
Induction motor (ASM):
Displays the referred imaginary system deviation for the adaptation circuit of the motor model.
Permanent-magnet synchronous motor (PMSM):
Displays the system deviation for speed adaptation.
r1762[0]: Angular deviation [rad-el] of the estimated EMF.
r1762[1]: Angular deviation [rad-el] of the low-level signal response for pulse technique.
Index:
[0] = Deviation model 1
[1] = Deviation model 2
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1), "Dynamic Drive Control" (DDC, p0096
= 2)
Description:
Induction motor (ASM):
Displays the referred real system deviation for the adaptation circuit of the motor model.
Permanent-magnet synchronous motor (PMSM):
Not used.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1), "Dynamic Drive Control" (DDC, p0096
= 2)
Description:
Sets the proportional gain of the controller for speed adaptation without encoder.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Description:
Displays the effective proportional gain of the controller for the speed adaptation.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
r1762[0...1]
Motor model deviation component 1 / MotMod dev comp 1
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
6721, 6730, 6731
Min Max
Factory
setting
- - -
r1763
Motor model deviation component 2 / MotMod dev comp 2
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
p1764[0...n]
Motor model without encoder speed adaptation Kp / MotMod woE n_adaKp
Access level:
4
Calculated:
p0340 = 1,3,4
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
-
Unit selection:
-
Func. diagram:
6730
Min Max
Factory
setting
0.000 100000.000
1000.000
r1765
Motor model speed adaptation Kp effective / MotM n_ada Kp act
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
p2001
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -