SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
37
2 Parameters
2.2 List of parameters
Description:
Displays the effective Motor Data Set (MDS) and the effective Encoder Data Sets (EDS).
Index:
[0] = Motor Data Set MDS effective
[1] = Encoder 1 Encoder Data Set EDS effective
[2] = Encoder 2 Encoder Data Set EDS effective
[3] = Reserved
Dependency:
Refer to: p0187, p0188
Note:
Value 99 means the following: No encoder assigned (not configured).
Description:
Displays the effective Command Data Set (CDS).
Dependency:
Refer to: p0810, p0811, r0836
Note:
The Command Data Set selected using a binector input (e.g. p0810) is displayed using r0836.
Description:
Displays the effective Drive Data Set (DDS).
Dependency:
Refer to: p0820, p0821, r0837
Note:
When selecting the motor data identification routine and the rotating measurement, the drive data set changeover is
suppressed.
Description:
Display and connector output for status word 1.
r0049[0...3]
Motor data set/encoder data set effective / MDS/EDS effective
Access level:
2
Calculated:
-
Data type:
Unsigned8
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
8565
Min Max
Factory
setting
- - -
r0050.0...1
CO/BO: Command Data Set CDS effective / CDS effective
Access level:
3
Calculated:
-
Data type:
Unsigned8
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
8560
Min Max
Factory
setting
- - -
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
CDS effective bit 0
ON
OFF
-
01
CDS effective bit 1
ON
OFF
-
r0051.0...1
CO/BO: Drive Data Set DDS effective / DDS effective
Access level:
2
Calculated:
-
Data type:
Unsigned8
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
8565
Min Max
Factory
setting
- - -
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
DDS effective bit 0
ON
OFF
-
01
DDS effective bit 1
ON
OFF
-
r0052.0...15
CO/BO: Status word 1 / ZSW 1
Access level:
2
Calculated:
-
Data type:
Unsigned16
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Ready for switching on
Yes
No
-
01
Ready
Yes
No
-
02
Operation enabled
Yes
No
-
03
Fault present
Yes
No
-
04
Coast down active (OFF2)
No
Yes
-