SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
421
2 Parameters
2.2 List of parameters
Description:
Sets the traversing blocks for sorting corresponding to their block number.
Procedure: Set p2624 = 0 --> 1.
Sorting is started and the parameters are automatically reset to zero once the operation has been completed.
Dependency:
Refer to: p2615, p2616, p2617, p2618, p2619, p2620, p2621, p2622, p2623
Note:
After sorting, the traversing blocks are written at the beginning of the memory in increasing sequence without any
gaps.
Description:
Sets the signal source to select the traversing block, bit 0.
Dependency:
Binector inputs p2625, p2626, p2627 and p2628 are used to select one of the maximum of 16 traversing blocks.
Refer to: p2626, p2627, p2628
Description:
Sets the signal source to select the traversing block, bit 1.
Dependency:
Binector inputs p2625, p2626, p2627 and p2628 are used to select one of the maximum of 16 traversing blocks.
Refer to: p2625, p2627, p2628
Description:
Sets the signal source to select the traversing block, bit 2.
Dependency:
Binector inputs p2625, p2626, p2627 and p2628 are used to select one of the maximum of 16 traversing blocks.
Refer to: p2625, p2626, p2628
p2624
EPOS traversing block sorting / Trav_block sort
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
Unsigned16
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3616
Min Max
Factory
setting
0 1 0
p2625
BI: EPOS traversing block selection bit 0 / Trav_blk sel bit 0
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3616, 3640
Min Max
Factory
setting
- - 0
p2626
BI: EPOS traversing block selection bit 1 / Trav_blk sel bit 1
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3616, 3640
Min Max
Factory
setting
- - 0
p2627
BI: EPOS traversing block selection bit 2 / Trav_blk sel bit 2
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3616, 3640
Min Max
Factory
setting
- - 0