SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
597
2 Parameters
2.2 List of parameters
[5] = Largest total utilization (max)
[6] = Reserved
[7] = Reserved
Dependency:
Refer to: r9976
Refer to: F01054, F01205
Note:
For index 3 ... 5:
The total utilizations are determined using all sampling times used. The largest total utilizations are mapped here.
The sampling time with the largest total utilization is displayed in r9979.
Total utilization:
Computing time load of sampling time involved including load from higher-priority sampling times (interrupts).
Description:
Displays the system utilization.
If the utilization is greater than 100%, fault F01054 is output.
Index:
[0] = Reserved
[1] = Computing time utilization
[2] = Reserved
[3] = Reserved
[4] = Reserved
[5] = Largest total utilization
[6] = Reserved
[7] = Reserved
Dependency:
Refer to: F01054, F01205
Note:
For index 1:
The value shows the total computing time load of the system.
For index 5:
The total utilization is determined using all sampling times used. The largest total utilization is mapped here. The
sampling time with the largest total utilization is displayed in r9979.
Total utilization:
Computing time load of sampling time involved including load from higher-priority sampling times (interrupts).
Description:
Diagnostics parameter to display additional information for internal software errors.
Note:
Only for internal Siemens troubleshooting.
Description:
Sets the delay time for testing the digital output.
Within this time, for a forced checking procedure of the digital output, the signal must have been detected via the
corresponding readback input (p10047).
Dependency:
Refer to: p10003, p10007, p10017, p10046
r9976[0...7]
System utilization / Sys util
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- [%]
- [%]
- [%]
r9999[0...99]
Software error internal supplementary diagnostics / SW_err int diag
Access level:
4
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
p10001
SI Motion delay time for test stop at DO (processor 1) / SI t_delay DO P1
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
4.00 [ms]
2000.00 [ms]
500.00 [ms]