SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
535
2 Parameters
2.2 List of parameters
Description:
Displays the actual station name for the onboard PROFINET interface on the Control Unit.
Description:
Displays the actual IP address for the onboard PROFINET interface on the Control Unit.
Description:
Displays the actual default gateway for the onboard PROFINET interface on the Control Unit.
Description:
Displays the actual subnet mask for the onboard PROFINET interface on the Control Unit.
Description:
Displays the actual DHCP mode for the onboard PROFINET interface on the Control Unit.
Value:
0:
DHCP off
2:
DHCP on, identification using MAC address
3:
DHCP on, identification via name of station
Notice:
When the DHCP mode is active (parameter value not equal to 0), PROFINET communication via this interface is no
longer possible! However, the interface can be used for commissioning tool such as STARTER or SCOUT.
Description:
Displays the MAC address for the onboard PROFINET interface on the Control Unit.
r8930[0...239]
PN Name of Station actual / PN Name Stat act
CU250S_V_PN
Access level:
3
Calculated:
-
Data type:
Unsigned8
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
r8931[0...3]
PN IP address actual / PN IP addr act
CU250S_V_PN
Access level:
3
Calculated:
-
Data type:
Unsigned8
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 255
-
r8932[0...3]
PN Default Gateway actual / PN Def Gateway act
CU250S_V_PN
Access level:
3
Calculated:
-
Data type:
Unsigned8
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 255
-
r8933[0...3]
PN Subnet Mask actual / PN Subnet Mask act
CU250S_V_PN
Access level:
3
Calculated:
-
Data type:
Unsigned8
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 255
-
r8934
PN DHCP Mode actual / PN DHCP Mode act
CU250S_V_PN
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 3 -
r8935[0...5]
PN MAC address / PN MAC addr
CU250S_V_PN
Access level:
3
Calculated:
-
Data type:
Unsigned8
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0000 hex
00FF hex
-