2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
200
List Manual, 09/2017, A5E33842890
Description:
Sets the signal source to select the total setpoint.
Dependency:
The selection of the total speed setpoint is automatically interconnected to the status word of the technology
controller (r2349.4) if the technology controller is selected (p2200 > 0) and operated in the mode p2251 = 0.
If the "hibernation mode" function is activated (p2398 = 1), an interconnection is made to r2399.7.
Refer to: p1109
Caution:
If the technology controller is to supply the total setpoint using p1109, then it is not permissible to disable the
interconnection to its status word (r2349.4).
If the "hibernation mode" function is activated, then it is not permissible to disable the interconnection to status word
r2399.
Description:
Sets the signal source for the total setpoint.
For p1108 = 1 signal, the total setpoint is read in via p1109.
Dependency:
The signal source of the total setpoint is automatically interconnected to the output of the technology controller
(r2294) if the technology controller is selected (p2200 > 0) and operated in the mode p2251 = 0.
If the "hibernation mode" function is activated (p2398 = 1), an interconnection is made to r2397[0].
Refer to: p1108
Caution:
If the technology controller is to supply the total setpoint using p1109, then it is not permissible to disable the
interconnection to its output (r2294).
If the "hibernation mode" function is activated, then it is not permissible to withdraw the interconnection to setpoint
r2398[0].
Description:
Sets the signal source to disable the negative direction.
Dependency:
Refer to: p1111
Description:
Sets the signal source to disable the positive direction.
Dependency:
Refer to: p1110
p1108[0...n]
BI: Total setpoint selection / Total setp sel
Access level:
4
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
CDS, p0170
Unit group:
-
Unit selection:
-
Func. diagram:
3030
Min Max
Factory
setting
- - 0
p1109[0...n]
CI: Total setpoint / Total setp
Access level:
4
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
T
Scaling:
p2000
Dyn. index:
CDS, p0170
Unit group:
-
Unit selection:
-
Func. diagram:
3030
Min Max
Factory
setting
- - 0
p1110[0...n]
BI: Inhibit negative direction / Inhib neg dir
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
CDS, p0170
Unit group:
-
Unit selection:
-
Func. diagram:
2505, 3040
Min Max
Factory
setting
- - 0
p1111[0...n]
BI: Inhibit positive direction / Inhib pos dir
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
CDS, p0170
Unit group:
-
Unit selection:
-
Func. diagram:
2505, 3040
Min Max
Factory
setting
- - 0