SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
419
2 Parameters
2.2 List of parameters
Description:
Sets the acceleration override for the traversing block.
The override refers to the maximum acceleration (p2572).
Dependency:
The number of indices depends on p2615.
Refer to: p2572, p2615, p2616, p2617, p2618, p2620, p2621, p2622, p2623, p2624
Description:
Sets the deceleration override for the traversing block.
The override refers to the maximum deceleration (p2573).
Dependency:
The number of indices depends on p2615.
Refer to: p2573, p2615, p2616, p2617, p2618, p2619, p2621, p2622, p2623, p2624
Notice:
If, when calculating the traversing profile, it is identified that the target position of the next block with the programmed
deceleration override will not be reached without direction reversal (flying block change), then the old (actual)
deceleration override remains effective.
Description:
Sets the required task for the traversing block.
Value:
1:
POSITIONING
2:
FIXED STOP
3:
ENDLESS_POS
4:
ENDLESS_NEG
5:
WAITING
6:
GOTO
7:
SET_O
8:
RESET_O
9:
JERK
Dependency:
The number of indices depends on p2615.
Refer to: p2615, p2616, p2617, p2618, p2619, p2620, p2622, p2623, p2624
p2619[0...n]
EPOS traversing block acceleration override / Trav_block a_over
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
p2615
Unit group:
-
Unit selection:
-
Func. diagram:
3616
Min Max
Factory
setting
1.0 [%]
100.0 [%]
100.0 [%]
p2620[0...n]
EPOS traversing deceleration override / Trav_block -a_over
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
p2615
Unit group:
-
Unit selection:
-
Func. diagram:
3616
Min Max
Factory
setting
1.0 [%]
100.0 [%]
100.0 [%]
p2621[0...n]
EPOS traversing block task / Trav_block task
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
Integer16
Can be changed:
U, T
Scaling:
-
Dyn. index:
p2615
Unit group:
-
Unit selection:
-
Func. diagram:
3616
Min Max
Factory
setting
1 9 1