SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
633
2 Parameters
2.2 List of parameters
Description:
Setting parameter for the run-time group in which instance DIV 0 of the divider is to be called.
Value:
5:
Run-time group 5
6:
Run-time group 6
9999: Do not calculate
Description:
Setting parameter for the run sequence of instance DIV 0 within the run-time group set in p20121.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description:
Sets the signal source of dividend X1 and divisor X2 of instance DIV 1 of the divider.
Index:
[0] = Dividend X0
[1] = Divisor X1
Description:
Display parameter for quotients Y = X1 / X2, the integer number quotients YIN, and division remainder MOD = (Y -
YIN) x X2 of instance DIV 1 of the divider.
Index:
[0] = Quotient Y
[1] = Integer number quotient YIN
[2] = Div remainder MOD
p20121
DIV 0 run-time group / DIV 0 RTG
CU250S_V
(FBLOCKS)
CU250S_V_CAN
(FBLOCKS)
CU250S_V_DP
(FBLOCKS)
CU250S_V_PN
(FBLOCKS)
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7222
Min Max
Factory
setting
5 9999
9999
p20122
DIV 0 run sequence / DIV 0 RunSeq
CU250S_V
(FBLOCKS)
CU250S_V_CAN
(FBLOCKS)
CU250S_V_DP
(FBLOCKS)
CU250S_V_PN
(FBLOCKS)
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7222
Min Max
Factory
setting
0 32000
300
p20123[0...1]
CI: DIV 1 inputs / DIV 1 inputs
CU250S_V
(FBLOCKS)
CU250S_V_CAN
(FBLOCKS)
CU250S_V_DP
(FBLOCKS)
CU250S_V_PN
(FBLOCKS)
Access level:
3
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
T
Scaling:
PERCENT
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7222
Min Max
Factory
setting
- - 0
r20124[0...2]
CO: DIV 1 quotient / DIV 1 quotient
CU250S_V
(FBLOCKS)
CU250S_V_CAN
(FBLOCKS)
CU250S_V_DP
(FBLOCKS)
CU250S_V_PN
(FBLOCKS)
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
PERCENT
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7222
Min Max
Factory
setting
- - -