SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
439
2 Parameters
2.2 List of parameters
Dependency:
This parameter is only active when the "Position feedback signal" function is activated (p2584.0 = 1).
Refer to: p2584, r2689
Description:
Display and connector output for the traversing block number for position feedback signal. Here, the block number of
the traversing blocks is displayed bit-coded, whose absolute target positions lie within the tolerance window around
the actual position.
Index:
[0] = Position feedback signal low
[1] = Position feedback signal high
Dependency:
This parameter is only active when the "Position feedback signal" function is activated (p2584.0 = 1).
Refer to: p2584, p2688
Note:
CO: r2689[0]: bit-coded display of traversing block numbers 0 to 31. CO: r2689[1]: bit-coded display of traversing
block numbers 32 to 63.
Description:
Sets a fixed setpoint for the position.
Dependency:
Refer to: p2642, p2648
Note:
As standard, the following BICO interconnection is established: CI: p2642 = r2690
Description:
Sets a fixed setpoint for the velocity.
Dependency:
Refer to: p2643
Note:
As standard, the following BICO interconnection is established: CI: p2643 = r2691
Description:
Sets a fixed setpoint for the acceleration override.
Dependency:
Refer to: p2572, p2644
Note:
As standard, the following BICO interconnection is established: CI: p2644 = r2692
The percentage value refers to the maximum acceleration (p2572).
r2689[0...1]
CO: EPOS position feedback signal display / Pos_FS display
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3616
Min Max
Factory
setting
- - -
p2690
CO: EPOS position fixed setpoint / Pos fixed value
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
Integer32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3618
Min Max
Factory
setting
-2147482648 [LU]
2147482647 [LU]
0 [LU]
p2691
CO: EPOS velocity fixed setpoint / v fixed value
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
Unsigned32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3618
Min Max
Factory
setting
1 [1000 LU/min]
40000000 [1000 LU/min]
600 [1000 LU/min]
p2692
CO: EPOS acceleration override, fixed setpoint / a_over fixed val
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3618
Min Max
Factory
setting
0.100 [%]
100.000 [%]
100.000 [%]