SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
399
2 Parameters
2.2 List of parameters
Description:
Sets the signal source for the position controller enable 1.
Dependency:
Refer to: r0899, p2550
Note:
The position controller is enabled by the following AND logic operation:
- BI: p2549
- BI: p2550
Description:
Sets the signal source for the position controller enable 2.
Dependency:
Refer to: p2549
Note:
The position controller is enabled by the following AND logic operation:
- BI: p2549
- BI: p2550
Description:
Sets the signal source for the "setpoint fixed" signal.
BI: p2551 = 1 signal:
The end of the positioning operation on the setpoint side is signaled and the positioning and standstill monitoring
activated.
BI: p2551 = 0 signal:
The start of a positioning operation or tracking mode on the setpoint side is signaled and the positioning and standstill
monitoring deactivated.
Dependency:
Refer to: p2554, r2683
p2549
BI: LR enable 1 / Enable 1
CU250S_V (Position
control)
CU250S_V_CAN
(Position control)
CU250S_V_DP
(Position control)
CU250S_V_PN
(Position control)
Access level:
1
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4015
Min Max
Factory
setting
- - 899.2
p2550[0...n]
BI: LR enable 2 / Enable 2
CU250S_V (Position
control)
CU250S_V_CAN
(Position control)
CU250S_V_DP
(Position control)
CU250S_V_PN
(Position control)
Access level:
1
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
CDS, p0170
Unit group:
-
Unit selection:
-
Func. diagram:
4015
Min Max
Factory
setting
- - 1
p2551
BI: LR setpoint signal fixed / Mess setp fixed
CU250S_V (Position
control)
CU250S_V_CAN
(Position control)
CU250S_V_DP
(Position control)
CU250S_V_PN
(Position control)
Access level:
1
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4020
Min Max
Factory
setting
- - 2683.2