Internal control/status words
G120 CU250S-2
05.09.2017
V4.7.9
Status word, monitoring functions 1 (r2197)
9
10
8
7
6
5
4
3
2
1
0
1
ZSW monitor 1
r2197
r2197
From speed signals
From speed signals
From speed signals
From speed signals
Status word, monitoring functions 1 (r2197)
Bit No.
1 = |n_act| n_min p1080
1 = |n_act| n_set
1 = |n_act| n_standstill p1226
1 = I_act I_threshold p2170
1 = Vdc_act Vdc_threshold p2172
1 = Vdc_act > Vdc_threshold p2172
1 = |n_act| speed threshold value 2 (p2155)
1 = |n_act| > speed threshold value 2 (p2155)
1 = n_act 0
1 = |n_act| > n_max
1 = Speed setpoint - actual value deviation within tolerance t_off
n_act = smoothed speed actual value r2169 [8010.2].
11
12
1 = Load missing
1 = |n_act| > n_max (with delay)
From monitoring functions
From monitoring functions
From monitoring functions
From monitoring functions
From monitoring functions
From monitoring functions
From monitoring functions
From monitoring functions
13
r2197.0
r2197.1
r2197.4
r2197.5
r2197.11
r2197.12
r2197.2
r2197.6
r2197.9
r2197.3
r2197.7
r2197.8
r2197.10
[8022.8]
[8010.8]
[8011.8]
[8022.8]
[8022.8]
[8010.8]
[8011.8]
[8022.8]
[8022.8]
[8022.8]
[8022.8]
[8023.8]
1 = |n_act| > n_max
[2510.2], [8023.1]
[2511.2]
[2511.2]
[2511.2]
[2511.2]
[2511.2]
[2511.2]
[2511.2]
[2511.2]
[2510.2]
[2510.2]
(F07901)