TMCP 16/32/48 

Installation Manual 

Issue 1 

 

 

 

 

 

Summary of Contents for TallyMan TMCP 16

Page 1: ...TMCP 16 32 48 Installation Manual Issue 1 ...

Page 2: ...2 of 26 Version History Issue Date Change Details 1 06 11 17 First Issue ...

Page 3: ...troller comms settings 13 Main backup modes 14 Testing comms 14 Operation 15 Startup 15 Main backup comms 15 PSU failure 15 Panel lock 15 Connections 16 Default IP settings 16 Pin out details 17 Ethernet 17 Serial RS422 18 GPI 1 16 19 GPI output 1 4 20 Weight and dimensions 22 TMCP 16 22 TMCP 32 23 TMCP 48 24 Safety 1 Installation 1 Earthing grounding 1 Mounting 1 Power 1 Ventilation 1 ...

Page 4: ...4 of 26 Warranty maintenance and repair 2 Failure during warranty 2 Technical support information 2 TSL returns procedure 2 Fault report details required 2 Packing 2 ...

Page 5: ...nd TMCP collectively All operational set up such as routing assignments mnemonics and tally management are programmed via a TallyMan controller currently this includes the models TM1 TM2 TM2 and TMC 1 as of June 2013 The TMCP is compatible with TallyMan controller software versions 1 83 onwards Instructions regarding operational setup can be found in the Control Panel section of the TallyMan Manua...

Page 6: ...n controller To add a TMCP in the TallyMan controller click Add New Component on the System properties pane and select Control Panel from the list of devices Figure 1 On the control panel properties pane under UCP type select TSL Control Panel ...

Page 7: ...7 of 26 Figure 2 Set the address size number of buttons and the number of pages you wish to be able to display and click Apply Click Edit Comms parameters and set the comms settings Figure 3 ...

Page 8: ...When connected via TCP IP the units act as server and client the TallyMan Controller acting as a server and the TMCP acting as a client The IP in the Control Panel Setup Communication window must be left blank at 0 0 0 0 or match the IP of the TallyMan Controller NOT the TMCP Figure 4 ...

Page 9: ...r with the default IP settings The default settings are available in the Default IP Settings section of this manual under Connections If the TMCP fails to establish comms with a system controller the No Comms menu will be presented Figure 5 To change the TMCP settings enter the Engineering Menu next page ...

Page 10: ... menu are displayed here Comms Status Figure 7 These buttons indicate the comms status The left button is illuminated green when the TallyMan controller has responded correctly to poll requests The orange buttons display the details of the TallyMan controller that the panel is connected to The right button is illuminated blue and when pressed toggles the current comms between main and backup setti...

Page 11: ...11 of 26 Active buttons Figure 8 These buttons are covered individually in the following sections ...

Page 12: ...he rotary encoder knob up to a maximum of 30 minutes The currently selected mode is illuminated green Panel lock mode is indicated by the presence of a padlock icon in the right hand edge of the rightmost button Figure 9 Panel lock may be deactivated by pressing and holding the rotary encoder knob until the padlock icon on the rightmost edge disappears PSU Pushing the setup PSU button in the engin...

Page 13: ...ess the octet to be changed it will be highlighted in green The value may now be adjusted by turning the rotary encoder knob Panel controller comms settings To set the TallyMan controller IP address press the Target IP button to access the below menu Figure 11 Target IP allows the user to set the IP of the TallyMan controller If the backup comms are set to IP the option to set the backup address w...

Page 14: ... currently selected option is shown in green Testing comms Ping Main and Ping Backup buttons are available in the comms menu pressing these buttons will initiate a ping to the target IP address The result of the latest poll is shown in the engineering menu This is a poll to the TallyMan controller using the TMCP protocol as opposed to a simple ping ...

Page 15: ...mms may be switched to backup via an external GPI or manually via the engineering menu for testing and maintenance or to force failover to a backup system in emergencies that do not meet the automatic failover criteria i e non response of the main controller to successive polls PSU failure Should a PSU that is set as fitted in the setup PSU menu fail a PSU failure notification will be reported via...

Page 16: ... DB9 Female Serial Comms with TallyMan controller GPI Input 1 16 DB25 Female Configurable as inputs or outputs Configured viaTallyMan controller GPI Output 1 4 DB9 Female 4 Isolated relay outputs Default IP settings The default settings of the TMCP are Network TCP IP Client IP Address 192 168 205 123 Subnet Mask 255 255 255 0 Default Gateway 192 168 205 254 The default Tallyman Controller settings...

Page 17: ...17 of 26 Pin out details Ethernet Signal Name RJ 45 Pin TX 1 TX 2 RX 3 EPWR Power 4 EPWR Power 5 RX 6 EPWR Power 7 EPWR Power 8 Figure 14 ...

Page 18: ...p Bits 1 Pin Numbers Signal Pin Numbers Signal 1 0v Chassis 6 0v 2 TX 7 TX 3 RX 8 RX 4 0v 9 0v 5 To connect serially to a TallyMan controller a crossover cable will be required RS422 crossover cable Signal TMCP TallyMan Signal 0v Chassis 1 1 0v TX 2 8 RX RX 3 7 TX 0v 4 4 0v 5 0v 6 6 0v TX 7 3 RX RX 8 2 TX 0v 9 9 0v ...

Page 19: ...o activate a GPI input the pin must be pulled to ground These GPI may be configured as inputs or outputs by the TallyMan controller GPI inputs will occupy the lowest numbered pins on the connector GPI outputs are open collector driver circuits 10K pull up to 5V Common ground appears on Pins 13 and 25 The circuit is capable of sinking approx 150mA to ground to activate relays etc An example of the ...

Page 20: ...Relay 4 4 Relay 2 9 0v 5 Relay 3 These GPI outputs consist of isolated relay contact pairs Current loading is rated at 0 5A at 125 VAC 1A at 24 VDC non inductive Common ground appears on Pin 9 The example below demonstrates the circuit required for GPI 1 on the GPI output 1 4 connector Output 2 uses pins 3 4 output 3 uses pins 5 6 and output 4 uses pins 7 8 ...

Page 21: ...21 of 26 Figure 16 ...

Page 22: ...22 of 26 Weight and dimensions TMCP 16 Height 1 RU Weight 1 12Kg Figure 17 All measurements in mm ...

Page 23: ...23 of 26 TMCP 32 Height 2 RU Weight 1 66 Kg Figure 18 All measurements in mm ...

Page 24: ...24 of 26 TMCP 48 Height 2 RU Weight 1 78 Kg Figure 19 All measurements in mm ...

Page 25: ...n to the supply circuit loading and switch on fault surges that will affect over current protection trips and switches etc Check that the fuse rating is correct for the local power mains supply Replacement fuses must be of the same rating and type for continued protection against fire risk No power supply cord is provided with this equipment The external power supply provided with this product is ...

Page 26: ...0 and ask for technical support who assist in diagnosing the fault and will provide a returns number RMA This will enable us to track the unit effectively and will provide some information prior to the unit arriving For each item this unique returns number must be included with the fault report sent with the unit A contact name and telephone number are also required with the fault report sent with...