2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
410
List Manual, 09/2017, A5E33842890
Description:
Sets the setpoint velocity for jog 2.
Dependency:
Refer to: p2588, p2590, p2591
Description:
Sets the traversing distance for incremental jog 1.
Dependency:
Refer to: p2585, p2589, p2591
Note:
Incremental jog 1 is started with BI: p2591 = 1 signal and BI: p2589 = 0/1 signal.
With BI: p2589 = 0 signal, incremental jog is interrupted.
Description:
Sets the traversing distance for incremental jog 2.
Dependency:
Refer to: p2586, p2590, p2591
Note:
Incremental jog 2 is started with BI: p2591 = 1 signal and BI: p2590 = 0/1 signal.
With BI: p2590 = 0 signal, incremental jogging is interrupted.
Description:
Sets the signal source for jog 1.
Dependency:
When jogging, the axis is accelerated or braked with the maximum acceleration/deceleration (p2572/p2573).
BI: p2591 = 0 signal
The axis endlessly moves with the setpoint velocity, jog 1 (p2585).
BI: p2591 = 1 signal
The axis traverses through a parameterized distance (p2585) with the setpoint velocity, jog 1 (p2587).
Refer to: p2572, p2573, p2585, p2587, p2591
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p2586
EPOS jog 2 setpoint velocity / Jog 2 v_set
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
Integer32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3610
Min Max
Factory
setting
-40000000 [1000 LU/min]
40000000 [1000 LU/min]
300 [1000 LU/min]
p2587
EPOS jog 1 traversing distance / Jog 1 distance
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
Unsigned32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3610
Min Max
Factory
setting
0 [LU]
2147482647 [LU]
1000 [LU]
p2588
EPOS jog 2 traversing distance / Jog 2 distance
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
Unsigned32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3610
Min Max
Factory
setting
0 [LU]
2147482647 [LU]
1000 [LU]
p2589
BI: EPOS jog 1 signal source / Jog 1 S_src
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3610, 3625
Min Max
Factory
setting
- - 722.3