SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
435
2 Parameters
2.2 List of parameters
5:
WAITING
6:
GOTO
7:
SET_O
8:
RESET_O
9:
JERK
Dependency:
Refer to: p2621
Description:
Displays the task parameter presently being processed in the "traversing blocks" operating mode.
Dependency:
Refer to: p2622
Note:
The following is displayed depending on the task:
FIXED STOP: Clamping torque (0 ... 65536 [0.01 Nm]) or clamping force (0 ... 65536 [N])
WAIT: Delay time [ms]
GOTO: Block number
SET_O: 1, 2, 3 --> direct output 1, 2 or 3 (both) is set
RESET_O: 1, 2, 3 --> direct output 1, 2 or 3 (both) is reset
JERK: 0 --> deactivate, 1 --> activate
Description:
Displays the task mode presently being processed.
Dependency:
Refer to: p2623
Description:
Displays the actual position for the following events:
- external block change via measuring probe (p2632 = 0, BI: p2661 = 0/1 signal).
- external block change via BI: p2633 (p2632 = 1, BI: p2633 = 0/1 signal).
- activate traversing task (BI: p2631 = 0/1 signal).
Dependency:
Refer to: p2631, p2632, p2633, p2661
r2676
CO: EPOS actual task parameter / Task para act
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
Integer32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3616
Min Max
Factory
setting
- - -
r2677
CO: EPOS actual task mode / Task mode act
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
Unsigned16
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3616
Min Max
Factory
setting
- - -
r2678
CO: EPOS external block change actual position / Ext BlckChg s_act
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
Integer32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3615, 3616, 3620
Min Max
Factory
setting
- [LU]
- [LU]
- [LU]