SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
605
2 Parameters
2.2 List of parameters
Description:
Sets the fail-safe digital input (F-DI) for the "STO" function.
Value:
0:
Static selected
1:
F-DI 0
2:
F-DI 1
3:
F-DI 2
255:
Static deselected
Dependency:
Refer to: p10022
Note:
If value = 0:
No terminal assigned, safety function always selected.
If value = 255:
No terminal assigned, safety function always deselected.
F-DI: Fail-safe Digital Input
STO: Safe Torque Off
Description:
Sets the fail-safe digital input (F-DI) for the "SS1" function.
Value:
0:
Static selected
1:
F-DI 0
2:
F-DI 1
3:
F-DI 2
255:
Static deselected
Dependency:
Refer to: p10023
Note:
If value = 0:
No terminal assigned, safety function always selected.
If value = 255:
No terminal assigned, safety function always deselected.
F-DI: Fail-safe Digital Input
SS1: Safe Stop 1
Description:
Sets the fail-safe digital input (F-DI) for the "SLS" function.
Value:
0:
Static selected
1:
F-DI 0
2:
F-DI 1
3:
F-DI 2
255:
Static deselected
Dependency:
Refer to: p10026
p10122
SI Motion STO input terminal (processor 2) / SI STO F-DI P2
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 255
0
p10123
SI Motion SS1 input terminal (processor 2) / SI SS1 F-DI P2
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 255
0
p10126
SI Motion SLS input terminal (processor 2) / SI SLS F-DI P2
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 255
0