SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
249
2 Parameters
2.2 List of parameters
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Note:
For bit 16 = 1:
Encoderless open-loop controlled operation not active.
For bit 16 = 0:
Encoderless open-loop controlled operation active.
Description:
Display and BICO output for the status word of the current controller.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Description:
Sets the time constant for the speed setpoint filter 1 (PT1).
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Description:
Display and connector output of the speed setpoint after setpoint limiting for the P component of the speed controller.
For U/f operation, the value that is displayed is of no relevance.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Refer to: r1439
Note:
In the standard state (the reference model is deactivated), r1438 = r1439.
17
Speed limiting control active
Yes
No
6640
23
Acceleration model activated
Yes
No
-
24
Moment of inertia estimator active
Yes
No
-
25
Load estimate active
Yes
No
-
26
Moment of inertia estimator stabilized
Yes
No
-
27
Moment of inertia estimator fast estimation
active
Yes
No
-
r1408.0...14
CO/BO: Status word current controller / ZSW I_ctrl
Access level:
4
Calculated:
-
Data type:
Unsigned16
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2530
Min Max
Factory
setting
- - -
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Current controller active
Active
Not active
-
01
Id control I component limiting
Active
Not active
6714
03
Voltage limiting
Active
Not active
6714
10
Speed adaptation limiting
Active
Not active
-
11
Speed adaptation speed deviation
Out tolerance
In tolerance
6730
12
Motor stalled
Yes
No
-
13
Separately excited synchronous motor is
excited
Yes
No
-
14
Current model SESM magnetizing excit.
current limited to zero
Yes
No
-
p1416[0...n]
Speed setpoint filter 1 time constant / n_set_filt 1 T
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
-
Unit selection:
-
Func. diagram:
6020, 6030
Min Max
Factory
setting
0.00 [ms]
5000.00 [ms]
0.00 [ms]
r1438
CO: Speed controller speed setpoint / n_ctrl n_set
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
p2000
Dyn. index:
-
Unit group:
3_1
Unit selection:
p0505
Func. diagram:
3001, 6020, 6031
Min Max
Factory
setting
- [rpm]
- [rpm]
- [rpm]